2023
DOI: 10.1039/d3cp02714g
|View full text |Cite
|
Sign up to set email alerts
|

Gold nanocluster-based fluorescent sensors forin vitroandin vivoratiometric imaging of biomolecules

Abstract: Gold nanoclusters (AuNCs) are highlighted as potential nanomaterials for ratiometric fluorescent probes due to their size- and structure-related tunable fluorescence wavelengths, biocompatibility, and resistance to photobleaching properties. Dual-emission AuNC-based fluorescent...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 96 publications
0
3
0
Order By: Relevance
“…Ratiometric measurements are based on self-calibration of signal intensity by recording two or more signal fluctuations induced by analytes, where one signal can be used as internal standard to normalize the others. Ratiometric measurements are independent of various analyte-independent confounding factors, which contributes to more accurate and reliable quantification [30].…”
Section: Optimization Of Working Condition Of Ratiometric Fluorescent...mentioning
confidence: 99%
See 1 more Smart Citation
“…Ratiometric measurements are based on self-calibration of signal intensity by recording two or more signal fluctuations induced by analytes, where one signal can be used as internal standard to normalize the others. Ratiometric measurements are independent of various analyte-independent confounding factors, which contributes to more accurate and reliable quantification [30].…”
Section: Optimization Of Working Condition Of Ratiometric Fluorescent...mentioning
confidence: 99%
“…Currently, most fluorescent probes are constructed based on the mechanism of intramolecular charge transfer (ICT), fluorescence resonance energy transfer (FRET), or PET [30]. However, the intramolecular conjugated structure composed of electron donor and electron acceptor is necessary for ICT, and the emission will also shift either red or blue.…”
Section: Possible Mechanism Of Fluorescence Quenching Of Induced By D...mentioning
confidence: 99%
“…For example, protein-stabilized Au NCs with great biocompatibility have been widely used for bioimaging, biosensing, and therapy [20]. In addition, thiolatecapped Au NCs with a precise gold atom number also show extensive applications in both in vitro and in vivo studies [21]. We have witnessed significant advancements in the development of Au NC-based sensing probes and therapeutic agents that exhibit improved sensitivity, selectivity, and stability.…”
Section: Introductionmentioning
confidence: 99%