Glomerular filtration rate measurement by “single-shot” injection of inulin

Abstract: In 14 ADPKD patients the total body clearance and the urinary clearance of inulin using the constant infusion method were compared with the "single-shot" technique. Triplicate measurements of both clearances by each infusion method were obtained in 12 out of 14 patients. A high correlation was found between the total body clearance and the urinary clearance for both the constant infusion method (r = 0.96) and the single injection technique (r = 0.96). The coefficient of variation for the total body clearance o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
93
2
5

Year Published

1995
1995
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 95 publications
(104 citation statements)
references
References 32 publications
4
93
2
5
Order By: Relevance
“…32 In the MDRD Study, the median coefficient of variation for repeated measurement of urinary clearance of iothalamate using bolus subcutaneous injection was 6.3% over 3 mo, whereas it was 18.7% in another study where iothalamate was administered using continuous subcutaneous infusion. 33,37 Plasma Clearance…”
Section: Urinary Clearancementioning
confidence: 99%
“…32 In the MDRD Study, the median coefficient of variation for repeated measurement of urinary clearance of iothalamate using bolus subcutaneous injection was 6.3% over 3 mo, whereas it was 18.7% in another study where iothalamate was administered using continuous subcutaneous infusion. 33,37 Plasma Clearance…”
Section: Urinary Clearancementioning
confidence: 99%
“…There is also a systematic bias to underestimate the glomerular filtration rate by means of the hyperbolic relation between the endogenous creatinine concentration and the glomerular filtration rate. Because it is generally impossible to guarantee the achievement of a balance between infusion and excretion rates within two hours, in common practice the required steady-state concentration level is tacitly replaced by the average of the actually measured values (42). This is prone to entail underestimation of the glomerular filtration rate by constant-infusion methods as a consequence of overly short experiment horizons.…”
Section: Discussionmentioning
confidence: 99%
“…Plasma was separated, placed on ice and then stored at −70°C before the assay. Inulin and PAH were measured in serum by colorimetric assays using anthrone and N-(1-naphthyl) ethylenediamine, respectively [14][15][16]. The mean of two baseline clearance periods represents GFR INULIN and ERPF, expressed per 1.73 m 2 .…”
Section: Methodsmentioning
confidence: 99%
“…Renal blood flow (RBF) was derived using ERPF/(1−haematocrit) and renal vascular resistance (RVR) was derived by dividing the mean arterial pressure by the RBF. All renal haemodynamic measurements were adjusted for body surface area [14,16]. Upon arrival at the renal physiology laboratory, participants were asked to void and this final volume completed the 24 h urine collection.…”
Section: Methodsmentioning
confidence: 99%