2017
DOI: 10.1016/j.jksus.2016.09.005
|View full text |Cite
|
Sign up to set email alerts
|

Geophysical mapping of contaminant leachate around a reclaimed open dumpsite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(13 citation statements)
references
References 23 publications
0
13
0
Order By: Relevance
“…Current density pseudo-section ( Figures 2-6) was produced from the real component data using a linear filter [20] of the KHFILT inversion software [31]. The Karous-Hjelt filter produces a 2D conductive model of the subsurface by converting the secondary magnetic field into current density depth [9,32]. In order to compensate for the reduction of VLF-EM with depth in a conducting medium, the skin depth of the inversion software was used [9].…”
Section: Acquisition Of Vlf-em Datamentioning
confidence: 99%
See 2 more Smart Citations
“…Current density pseudo-section ( Figures 2-6) was produced from the real component data using a linear filter [20] of the KHFILT inversion software [31]. The Karous-Hjelt filter produces a 2D conductive model of the subsurface by converting the secondary magnetic field into current density depth [9,32]. In order to compensate for the reduction of VLF-EM with depth in a conducting medium, the skin depth of the inversion software was used [9].…”
Section: Acquisition Of Vlf-em Datamentioning
confidence: 99%
“…The Karous-Hjelt filter produces a 2D conductive model of the subsurface by converting the secondary magnetic field into current density depth [9,32]. In order to compensate for the reduction of VLF-EM with depth in a conducting medium, the skin depth of the inversion software was used [9]. The separation distance used for the acquisition of data was a factor of available space.…”
Section: Acquisition Of Vlf-em Datamentioning
confidence: 99%
See 1 more Smart Citation
“…It can also be used in the management of groundwater to prevent over-withdrawal that may cause aquifer damage, and in policy formulation. The data can be integrated with other geophysical and geological data for multipurpose applications in landfill siting, groundwater pollution control, dam site selection and other civil engineering applications [1] , [2] , [3] , [4] . The data can form a part of a large database or repository for regional hydrogeological study in Nigeria and Africa.…”
Section: Value Of the Datamentioning
confidence: 99%
“…Due to the easy operation of the instrument, the speed of field surveys, and low operating costs, this method is particularly well suited for a rapid initial survey and has been widely used in many geophysical studies since the 1960s [2]. On the other hand, the Resistivity method is the most widely used geophysical method for the evaluation of waste disposal sites because it is fast, reliable, affordable, and nondestructive [3]. Both methods have been successfully used to identify and evaluated landfills, leachate flow, groundwater contamination, and geo-electric layers [2]- [6].…”
Section: Introductionmentioning
confidence: 99%