2018
DOI: 10.1259/dmfr.20170467
|View full text |Cite
|
Sign up to set email alerts
|

Geometric distortion of panoramic reconstruction in third molar tilting assessments: a comprehensive evaluation

Abstract: To evaluate the geometric distortion of tilting of mandibular third molars with respect to second molars on panoramic reconstruction. Methods: Cone-beam CT (CBCT) reconstructions of 160 third molars, obtained due to an indication of risk of inferior alveolar nerve damage during surgery, were used. CBCT-reconstructed panoramic images were used as bi-dimensional (2D) images, to avoid distortions other than geometric distortions. The angle between the second and the third molar was measured in 2D and three-dimens… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(17 citation statements)
references
References 27 publications
(34 reference statements)
0
17
0
Order By: Relevance
“…One must be aware of the geometric distortion of the dental arch on a panoramic image . Additionally, positional errors when placing the patient in the panoramic X‐ray machine may result in discrepancies between the molar angulation measurements at T1 and T2.…”
Section: Discussionmentioning
confidence: 99%
“…One must be aware of the geometric distortion of the dental arch on a panoramic image . Additionally, positional errors when placing the patient in the panoramic X‐ray machine may result in discrepancies between the molar angulation measurements at T1 and T2.…”
Section: Discussionmentioning
confidence: 99%
“…In order to test the detection time and the detection degree of the proposed geometric statistics-based micro-distortion detection technology for lidar scanning signals, the experiment was compared with methods in [8,9]. The experimental platform was built by the control host of Intel B360 i7-8700.…”
Section: Results and Analysis Of Simulation Experimentsmentioning
confidence: 99%
“…Through experiments, time-consuming results of the three methods were recorded, as shown in Table 1. The proposed method and methods in [8,9] were used to detect the micro-distortion of 3000 sets for lidar scanning signals. Through experiments, time-consuming results of the three methods were recorded, as shown in Table 1.…”
Section: Results and Analysis Of Simulation Experimentsmentioning
confidence: 99%
See 2 more Smart Citations