Geometric‐based PID control design with selective harmonic mitigation for DC–DC converters by imposing a norm bound on the sensitivity function

Abstract: The DC-DC converters usually interfaces renewable energy sources in DC microgrids which may be contaminated by harmonic perturbations that adversely affect performance, creates stability and protection problems in a DC grid system. In this paper, the authors propose the use of the popular proportional-integral-derivative (PID) controller to mitigate selected harmonics. The solution is obtained by computing the complete set of stabilising controllers and imposing a bound on the sensitivity function. Using matri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 25 publications
0
3
0
2
Order By: Relevance
“…There are two parallel lines between the DC and AC buses each one comprising three inverters. Under the integrated bus, the harmonic powers are transmitted through the inverters on line 1 27 . Total reference active power is 46 kW (7 kW is allocated to diesel generators and 39 kW to wind turbines).…”
Section: The Proposed Control Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…There are two parallel lines between the DC and AC buses each one comprising three inverters. Under the integrated bus, the harmonic powers are transmitted through the inverters on line 1 27 . Total reference active power is 46 kW (7 kW is allocated to diesel generators and 39 kW to wind turbines).…”
Section: The Proposed Control Systemmentioning
confidence: 99%
“…Under the integrated bus, the harmonic powers are transmitted through the inverters on line 1. 27 Total reference active power is 46 kW (7 kW is allocated to diesel generators and 39 kW to wind turbines). Total reference reactive power is 15 kVAr (9 kVAr is allocated to diesel generators and 6 kVAr to wind turbines).…”
Section: Network Understudymentioning
confidence: 99%
“…das chaves eletrônicas que os compõem. Na literatura, uma grande parte dos trabalhos dedicados à síntese de controle para estes dispositivos são baseados em sistemas médios e em sinais de modulação de largura de pulso, veja a referência recente Magossi et al (2020) que propõe a síntese de um controlador PID para conversores de potência CC-CC com a finalidade de atenuar harmônicas selecionadas. Embora os resultados disponíveis a partir desta abordagem sejam amplamente empregados na indústria e constantemente aprimorados pela comunidade científica, a possibilidade de realizar o projeto utilizando diretamente o sistema original, sem o intermédio de sinais moduladores, permite tratar o problema sob uma perspectiva teórica mais abrangente, com possibilidade de resultados menos conservadores e maior chance de generalizações.…”
Section: Introdu ç ãOunclassified
“…For instance, in photovoltaic systems the output voltage of the photovoltaic arrays needs to be increased in order to be connected to the grid (Vázquez et al, 2013). There are several topologies of DC-DC converters in the literature which can provide output voltage greater than input, and among them, the boost converter has a simple structure (Ivanovic et al, 2014;Magossi et al, 2020).…”
Section: Introductionmentioning
confidence: 99%