Geometric alignment and chromatic calibration of serial radiographic images

Abstract: Very user-friendly software was developed. The manipulator needs to scan the radiographs only one time. The software performs all subsequent processing steps.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…), and the mean pixel values were evaluated in interdental alveolar bone (from the ABC to the root apex) using I magej software (NIH, Bethesda, MD, USA), as previously described (33). Before being used to make the measurements, I magej software was calibrated and tested using radiographs of an aluminium wedge comprising a set of standard gray values, as previously described (34). This calibration was repeated in the analysis of all radiographs with the same wedge in identical positions throughout the same gray values.…”
Section: Methodsmentioning
confidence: 99%
“…), and the mean pixel values were evaluated in interdental alveolar bone (from the ABC to the root apex) using I magej software (NIH, Bethesda, MD, USA), as previously described (33). Before being used to make the measurements, I magej software was calibrated and tested using radiographs of an aluminium wedge comprising a set of standard gray values, as previously described (34). This calibration was repeated in the analysis of all radiographs with the same wedge in identical positions throughout the same gray values.…”
Section: Methodsmentioning
confidence: 99%
“…A number of studies have used exposures of the aluminum step wedge model as a reference to evaluate bone density [9,11,15] or monitoring bone changes [11,14,16]. All of these methods have reported accuracy in recording evaluating changes in bone.…”
Section: Discussionmentioning
confidence: 99%
“…Graf et al [20] designed a simple paralleling instrument for superposition of the molar regions. Dornier et al [21] used this position device to minimize the projection divergence in his study. In our study, a wooden box was utilized to minimize geometric variation of the exposures.…”
Section: Discussionmentioning
confidence: 99%
“…The use of an X-ray wedge calibration tool has also been proposed by some researchers groups (Bolander et al, 1990;De Josselin de Jong et al, 1989;Dornier et al, 2004;Escarpinati et al, 2002;Haidekker et al, 2004;Martin et al, 1990;Pearson et al, 2002;Saiki et al, 1993;Symmons, 2004) as a suitable tool to normalize radiographs. Nevertheless up to now in the orthopaedic scenario the assessment of bone tissue is still monitored by using the single energy X-ray exam, where no additional device is incorporated during the routine protocol.…”
Section: Introductionmentioning
confidence: 99%