Generation and Application of Ultra-High-Intensity Magnetic Field Gradient Pulses for NMR Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
100
0
3

Year Published

2002
2002
2008
2008

Publication Types

Select...
5
3

Relationship

3
5

Authors

Journals

citations
Cited by 154 publications
(103 citation statements)
references
References 26 publications
0
100
0
3
Order By: Relevance
“…Typische Parameter für 1 H-PFG-NMR-Untersuchungen mit der 13-Intervall-Pulsfolge am Spektrometer Fegris 400NT (400 MHz): [18] (908-1808)-HF-Pulsabstand t = 500 ms, Breite der gepulsten …”
Section: Experimentellesunclassified
“…Typische Parameter für 1 H-PFG-NMR-Untersuchungen mit der 13-Intervall-Pulsfolge am Spektrometer Fegris 400NT (400 MHz): [18] (908-1808)-HF-Pulsabstand t = 500 ms, Breite der gepulsten …”
Section: Experimentellesunclassified
“…Recent progress in the PFG NMR instrumentation and the thus obtained enhanced sensitivity have made it possible that today even in this short-time limit of PFG NMR more profound information may be deduced 18,19,24 .…”
Section: Short-time Limit Of the Effective Diffusivitymentioning
confidence: 99%
“…The diffusion measurements were carried out at a proton resonance frequency of 400 MHz (nhexane) and a fluorine resonance frequency of 376.4 MHz (tetrafluoromethane) using the home-built NMR spectrometer FEGRIS 400 NT 19 . The spectrometer is equipped with a ultrahigh intensity pulsed field gradient facility consisting of an actively shielded Anti-Helmholtz gradient coil and two Techron gradient current amplifiers connected in push-pullconfiguration 19 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The magnet is a wide bore 9.4T superconducting type (Bruker, Germany) and is used with a MARAN ULTRA console (Resonance Instruments, GB) with a Direct Binary Coded Current Source [20] for gradient pulse generation, whilst the instrument is triggered at a constant mains voltage phase to avoid hum artefacts. Using a stimulated gradient echo sequence with compensation for a shift in echo position caused by imperfect gradient pulses [20], a sample volume of 0.5ml is tested in the actively shielded anti-helmholtz type probe at a range of temperatures for distilled water and gellan gum. These experiments allow rapid assessment of the stability of the preparation and its sensitivity to minor changes in temperature.…”
Section: P O S T P R I N T ( P R O O F C O P Y )mentioning
confidence: 99%