1967
DOI: 10.1139/v67-312
|View full text |Cite
|
Sign up to set email alerts
|

Gas chromatographic studies of isotopically labelled ethylenes

Abstract: The use of long, silver nitrate – ethylene glycol gas chromatographic columns has permitted a near base line separation to be achieved for deuterated olefins differing by only one deuterium atom. All of the six deuterated ethylenes and two deuterated butenes have been studied, and good separations have been obtained between the different isotopic species. The isotope effects (KD/KH) on the retention times have been calculated. Evidence of a difference in the relative retention times of two of the ethylene-d2 i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

1
4
0

Year Published

1968
1968
2002
2002

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(5 citation statements)
references
References 0 publications
1
4
0
Order By: Relevance
“…I t can be readily observed that the heavy sterols are eluted faster than the analogous light sterols. This isotope effect has been reported in a large number of cases (4,(11)(12)(13) and has been discussed by Saha and Sweeley (14). It is of greater magnitude and more easily detected when the molecules under study contain a large number of hydrogen atoms.…”
supporting
confidence: 69%
“…I t can be readily observed that the heavy sterols are eluted faster than the analogous light sterols. This isotope effect has been reported in a large number of cases (4,(11)(12)(13) and has been discussed by Saha and Sweeley (14). It is of greater magnitude and more easily detected when the molecules under study contain a large number of hydrogen atoms.…”
supporting
confidence: 69%
“…The radioactive ethylene was first separated on a 1.83 m X 6.25 mm stainless steel silver nitrate ethylene-glycol coated Gas-Chrom R (45-60 mesh firebrick, Applied Science Laboratories, Inc. State College, Pa.) column (3) at 0 C with a flow rate of 50 cc/min. This column effectively separated the saturated hydrocarbons from the unsaturated ones ( Fig.…”
mentioning
confidence: 99%
“…Ethylene was analyzed in a Perkin-Elmer 900 gas chromatograph using a flame ionization detector with helium as the carrier gas. Separations were made at -20 C on a 63-foot by one-eighth inch stainless steel column packed with Chromosorb R which had been coated with a saturated silver nitrate-ethylene glycol solution (1). cis-and trans-Dideuteroethylenes were analyzed in a Perkin-Elmer Model 21 infrared spectrophotometer using a 3.3-cm micro gas cell.…”
mentioning
confidence: 99%
“…On the basis of gas chromatography data, deuteration has been shown to increase the stability of the silver ion-ethylene complex (1,10). Therefore, if ethylene does bind to a metallic receptor site, deuterated ethylene might be expected to be slightly more effective than ordinary ethylene.…”
mentioning
confidence: 99%