2011
DOI: 10.1149/1.3551491
|View full text |Cite
|
Sign up to set email alerts
|

Galvanic Displacement of Nanostructured Gold for Flavoenzyme Adsorption in Biotechnology

Abstract: Sensors are the devices which are composed of an active sensing material with a signal transducer. The recent development in the nanotechnology has paved the way for large number of new materials and devices of desirable properties which have useful functions for numerous electrochemical sensor and biosensor applications. In this work, results on the galvanic displacement of gold on silicon in different electrolytes will be presented. The growth of the gold films is characterized and the interfacial behavior w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 13 publications
(17 reference statements)
0
4
0
Order By: Relevance
“…The adhesion parameter, b was calculated from slope of the linear dependencies shown in this Figure , and the calculated values are given in the Table 3. The larger value of the adhesion parameter b means the better adhesion of the coating with substrate [23][24][25][26][30][31][32]. From Table 3, it can be seen that the Cu coatings obtained at 33 and 67 mA cm −2 with ultrasound stirring of the electrolyte showed better adhesion than those obtained without the electrolyte stirring.…”
Section: Analysis Of Mechanical Properties Of the Copper Coatings Electrodeposited On The Brass Cathodementioning
confidence: 96%
See 3 more Smart Citations
“…The adhesion parameter, b was calculated from slope of the linear dependencies shown in this Figure , and the calculated values are given in the Table 3. The larger value of the adhesion parameter b means the better adhesion of the coating with substrate [23][24][25][26][30][31][32]. From Table 3, it can be seen that the Cu coatings obtained at 33 and 67 mA cm −2 with ultrasound stirring of the electrolyte showed better adhesion than those obtained without the electrolyte stirring.…”
Section: Analysis Of Mechanical Properties Of the Copper Coatings Electrodeposited On The Brass Cathodementioning
confidence: 96%
“…Equation ( 2) was used to calculate the critical reduced depth, b, parameter representing an estimation of adhesion of any coating with substrate [23][24][25][26][30][31][32]. The value of the parameter n in Equation ( 2) is either 1.2 or 1.8, and for "soft coatings on hard substrate" like the Cu coatings on the brass substrate analyzed here, the value n of 1.8 was taken [26,30].…”
Section: Analysis Of Mechanical Properties Of the Copper Coatings Electrodeposited On The Brass Cathodementioning
confidence: 99%
See 2 more Smart Citations