2016 International Conference on Computation of Power, Energy Information and Commuincation (ICCPEIC) 2016
DOI: 10.1109/iccpeic.2016.7557270
|View full text |Cite
|
Sign up to set email alerts
|

Fuzzy controlled three port DC-DC converter fed DC drive for PV system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…2(d), S 1 is turned on under ZVS at t 3 , the voltage across the primary winding of the transformer nearly keeps v p = −V Cc . i L1 still increases linearly as in (1), and i L2 decreases linearly as follow:…”
Section: A Modal Analysis and Soft Switching Realizationmentioning
confidence: 85%
See 2 more Smart Citations
“…2(d), S 1 is turned on under ZVS at t 3 , the voltage across the primary winding of the transformer nearly keeps v p = −V Cc . i L1 still increases linearly as in (1), and i L2 decreases linearly as follow:…”
Section: A Modal Analysis and Soft Switching Realizationmentioning
confidence: 85%
“…The peak current on the secondary winding of the transformer I m can be obtained as: (1), and i L2 decreases linearly as in (5). L m experiences two processes during t 2 to t 5 , first forward being discharged and then reverse being charged, respectively.…”
Section: A Modal Analysis and Soft Switching Realizationmentioning
confidence: 99%
See 1 more Smart Citation
“….Here, ( )refers to the switching frequency, ( ) indicates the DC link power (i.e., the input power of B4-Inverter).The rating of the output capacitors 01 02 is derived from Equation ( 14) below for the minimum pulse width as done by [4] 01,02 =~× × 2 = 0.83 (0.03 × 48) × 314 × 2 = 917 (14) where ( ) indicates the angular frequency, permissible ripple voltage (~) in the output capacitors ( 01 02 ), which is considered to be the closest possible value, and therefore the output capacitors value of1000 is chosen. The current rating of ITPC converter and B4-Inverter switches is estimated by Equation (15,16) [9] = { +≈ } (15) = 1.25{0.83 + 0.8715} = 1.0893 (16) where represents the DC link current (i.e., the input current of B4-Inverter),≈ is the output ripple current in the ITPC converter and B4-Inverter, which is taken as 5% of maximum current and is computed as 0.08715 A, and the safety margin is taken to be 1.25 for the purpose of design.…”
Section: Hardware Component Selectionmentioning
confidence: 99%
“…Energy storage element, such as the battery, is necessary for improving the system dynamics and steady-state characteristics. An Integrated Three Port Converter (ITPC) interfaced with solar, battery and motor, at the same time, can be considered to be a right candidate for a renewable power system and has gained a lot of research interest recently [3][4][5].…”
Section: Introductionmentioning
confidence: 99%