2017
DOI: 10.1063/1.4975267
|View full text |Cite
|
Sign up to set email alerts
|

Fundamental study of reduction graphene oxide by sodium borohydride for gas sensor application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…Figure 6 indicates the presence of eight absorption bands in the FTIR spectrum of GO. The absorption peaks located at 3541–3367 cm −1 can be ascribed to O–H group stretching vibration, while the peaks between 2907 and 2232 cm −1 correspond to the asymmetric and symmetric stretching vibrations of C–H [ 28 , 29 ]. The bands observed at 1726 cm −1 , 1615 cm −1 , and 1416 cm −1 are attributed to C=O, C=C, and C–O–C stretching vibrations, respectively [ 30 ].…”
Section: Resultsmentioning
confidence: 99%
“…Figure 6 indicates the presence of eight absorption bands in the FTIR spectrum of GO. The absorption peaks located at 3541–3367 cm −1 can be ascribed to O–H group stretching vibration, while the peaks between 2907 and 2232 cm −1 correspond to the asymmetric and symmetric stretching vibrations of C–H [ 28 , 29 ]. The bands observed at 1726 cm −1 , 1615 cm −1 , and 1416 cm −1 are attributed to C=O, C=C, and C–O–C stretching vibrations, respectively [ 30 ].…”
Section: Resultsmentioning
confidence: 99%
“…Also, the transmittance is higher in the AuNPs/rGO sample. The absence of the 3450 cm −1 peak shows the fact that the GO was reduced, this peak is an indicator of the O-H stretch [26,[28][29][30]. The morphological study of the AuNPs/rGO sample was also done by the SEM, and the results are presented in Figure 6.…”
Section: Resultsmentioning
confidence: 99%
“…A wet chemical route through Hummers' method for the synthesis of functionalized rGO was achieved by Panda et al [8], for which the sensing properties (~71% sensitivity against 30 ppm CO) were used to detect low-concentration CO at room temperature and atmospheric pressure under ambient humidity. Muda et al [143] also reported on the fabrication of a gas sensor based on a vacuum method to achieve a homogenous and uniform thin film of multi-layer rGO on a plastic substrate. The fabricated sensor was used to detect NO 2 , and a sensitivity of ~25% over 50 ppm gas concentration was reported.…”
Section: Surface Functionalization Of Graphene/go/rgo With Metal Oxid...mentioning
confidence: 99%