2016
DOI: 10.18203/issn.2455-4510.intjresorthop20164172
|View full text |Cite
|
Sign up to set email alerts
|

Functional outcome of anterior cruciate ligament reconstruction with quadruple hamstring tendon graft using EndoButton and bioabsorbable interference screw: minimum 2-year follow-up

Abstract: <p class="abstract"><strong>Background:</strong> Anterior cruciate ligament (ACL) is the most common ligament to be torn in the knee joint and ACL reconstruction (ACLR) is one of the most commonly performed surgery in orthopaedics nowadays. This study evaluated short term results of anterior cruciate ligament reconstruction with quadruple hamstring tendon (QHT) graft using EndoButton for femoral fixation and Bio absorbable interference screw for tibial fixation.</p><p class="abstract… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…QHT graft are satisfactory (Shishir Murugharaj Suranigi, 2016). [14] In this study the postoperative complications at 24th weeks was pain (5%) and infection (1.7%). Pain was more in group 2 (6.7%) in comparison to group 1 (3.3%), infection was present in group 2 (3.3%) whereas no infection was reported in group 1.…”
mentioning
confidence: 52%
“…QHT graft are satisfactory (Shishir Murugharaj Suranigi, 2016). [14] In this study the postoperative complications at 24th weeks was pain (5%) and infection (1.7%). Pain was more in group 2 (6.7%) in comparison to group 1 (3.3%), infection was present in group 2 (3.3%) whereas no infection was reported in group 1.…”
mentioning
confidence: 52%
“…Hill [17] Chidanand et al [14] (2016) Quadruple Semitendinosus graft Endobutton Suture disc 2 years Shishir [20] M et al (2016) Quadruple Hamstring Graft Endobutton Bioabsorbable Interference screw 2 years Jagtap et al [15] (2017) Single Bundle Semitendinosus graft Endobutton Suture disc 1 year…”
Section: Author and Year Of Publisher Graft Used Femoral Fixation Tibial Fixation Duration Of Follow Upmentioning
confidence: 99%
“…Agni et al [19] [20] et al average preoperative score was 64.45 and post-operative at the end 6 months was 83.00 as shown in Table 17. [20] et al…”
Section: Author and Year Of Publisher Graft Used Femoral Fixation Tibial Fixation Duration Of Follow Upmentioning
confidence: 99%