Functional MRI 1996
DOI: 10.1007/978-88-470-2194-5_4
|View full text |Cite
|
Sign up to set email alerts
|

Functional MRI: The Environment and Technology for Clinical Application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

1996
1996
2002
2002

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…An oculomotor paradigm requiring eye movement was used to test the sighting visor device (16,18). This visually guided saccade task (19) was chosen, as the sighting system may be expected to disrupt this activation pattern due to distraction from the eye movement task associated with the sighting system.…”
Section: Imaging Protocolmentioning
confidence: 99%
See 1 more Smart Citation
“…An oculomotor paradigm requiring eye movement was used to test the sighting visor device (16,18). This visually guided saccade task (19) was chosen, as the sighting system may be expected to disrupt this activation pattern due to distraction from the eye movement task associated with the sighting system.…”
Section: Imaging Protocolmentioning
confidence: 99%
“…MR imaging was performed on either a 1.5 or 3.0 T whole-body scanner (55 cm clear bore magnet Signa; General Electric Medical Systems, Milwaukee, WI) equipped with resonant gradient EPI (Advanced NMR Systems, Wilmington, MA) and data handling capabilities designed for fMRI as previously described (8,16). Gradientecho EPI (17) at 1.5 T used acquisition parameters as follows: TR 3000 msec, TE 50 msec, field of view (FOV) 40 ϫ 20, voxel size 3.1 ϫ 3.1 ϫ 5.0 mm 3 , slice thickness/gap 5/1 mm, and number of slices 9.…”
Section: Imaging Protocolmentioning
confidence: 99%
“…Data acquisition is readily and effidata into and out of the scan room, thereby producing no degradaciently achieved by the MR technologist on this system. tion in the SNR of the images [22,33,46,47]. The color highAs the data from this comprehensive protocol are of various resolution LCD projector is enclosed in an RF isolation cabinet types including conventional MRI, EPI, and TPI, efficient autoand projects visual stimuli via a lens onto a rear-projection screen mated analysis requires conversion to a common format.…”
Section: Synchronization Control System (Scs)mentioning
confidence: 99%
“…To calibrate the responses of the various maps, four maps are derived using software customized to superimpose graduated color regions of activation/deactivation, calculated using a tubes containing the calibration solutions (30-40 mM NaCl, 80-100 mM NaCl, 50% deuterated H 2 O, and 100% H 2 O) were placed two-tailed Student t test [49], over gray-scale anatomic images [33,47]. The maps can be viewed in a tiled multislice format or around the inside of the RF coil.…”
Section: Analysis and Viewingmentioning
confidence: 99%