FT-IR microspectroscopy for microbiological studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
64
0
1

Year Published

2005
2005
2013
2013

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 93 publications
(67 citation statements)
references
References 14 publications
2
64
0
1
Order By: Relevance
“…Absorption spectra with a low noise level were obtained by setting the microscope aperture at about 100 lm · 100 lm [9]. The background spectrum was collected before each measurement and no baseline correction was required on the spectra.…”
Section: Ft-ir Microspectroscopymentioning
confidence: 99%
“…Absorption spectra with a low noise level were obtained by setting the microscope aperture at about 100 lm · 100 lm [9]. The background spectrum was collected before each measurement and no baseline correction was required on the spectra.…”
Section: Ft-ir Microspectroscopymentioning
confidence: 99%
“…Two main different types of infrared microscopy can be used: the first, conventional, allows the collection of the IR absorption spectra from a microvolume within the sample, with a spatial resolution not only due to the diffraction limit of Mid IR light (3-10 μm), but also to the level of the absorbed light. For these reasons, a spectrum of good quality can be collected by an area larger than 20 μm x 20 μm -when using a nitrogen cooled Mercury Cadmium Telluride (MCT) detector (Orsini et al, 2000). Thanks to the variable aperture of the microscope, it is possible to select a small area of few tens of microns within the sample, enabling the study of intact cells (Tanthanuc et al, 2010;Thumanu et al, 2009;Ami et al, 2008;Wood et al, 2008), tissues (Choo et al, 1996) and whole model organisms, as nematodes (Diomede et al, 2010;Ami et al, 2004).…”
Section: Infrared Microspectroscopy Applied To the Study Of Intact Cementioning
confidence: 99%
“…Typically, measurements on biomolecules and on complex biological systems, such as cells and tissues, are carried out in transmission, employing suitable IR transparent supports, for instance of barium fluoride or zinc selenide. However, sometimes, it could be useful to work in ATR when the samples of interest are highly absorbing or when they cannot be easily transferred onto an opportune infrared support (Walsh et al, 2007;Orsini et al, 2000). Indeed, in ATR measurements the sample is placed in contact with the ATR element (diamond, germanium, etc) characterized by a refractive index higher than that of the sample.…”
Section: Infrared Microspectroscopy Applied To the Study Of Intact Cementioning
confidence: 99%
“…This method has been extensively used in recent years for the study of microbial surfaces, and the identification and classification of microorganisms [20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%