2022
DOI: 10.3390/jcm11175201
|View full text |Cite
|
Sign up to set email alerts
|

Fractional Carbon Dioxide Laser Improves Vaginal Laxity via Remodeling of Vaginal Tissues in Asian Women

Abstract: Background: Vaginal laxity (VL) is characterized by the relaxing of the vaginal wall that affects the quality of life and sexual function of patients. The current management of VL such as Kegel exercises and topical or systemic hormonal replacement results in unsatisfactory outcomes; thus, novel modalities are needed to improve the efficacy. Vaginal fractional carbon dioxide (CO2) laser treatment has shown growing applications for the treatment of VL, but results show nonconformities due to the lack of objecti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 23 publications
(43 reference statements)
0
4
0
Order By: Relevance
“…The Vaginal Introitus's Viveve Treatment to Evaluate Effectiveness (VIVEVE I) trial was the first randomized control trial with radiofrequency in the therapy of vaginal laxity. A single RF treatment was proven to be safe and was associated with the improvement of vaginal laxity and sexual function [37].…”
Section: Discussionmentioning
confidence: 99%
“…The Vaginal Introitus's Viveve Treatment to Evaluate Effectiveness (VIVEVE I) trial was the first randomized control trial with radiofrequency in the therapy of vaginal laxity. A single RF treatment was proven to be safe and was associated with the improvement of vaginal laxity and sexual function [37].…”
Section: Discussionmentioning
confidence: 99%
“…Each technology provides parameters and precise protocols for treatment. Three treatments at 1‐month intervals are recommended with maintenance treatments performed as a single treatment between 6‐ and 12‐month follow‐up based upon the duration of outcomes 30–38 …”
Section: Laser and Ebd Genitourinary Applicationsmentioning
confidence: 99%
“…The settings on the device are provided by each manufacturer. [30][31][32][33][34][35][36][37][38][39][40] In general, the fluence (for microablative CO 2 laser) is in the low range of approximately 250-300 mJ/cm 2 and the spacing of the microbeams is approximately 1 mm apart. The handpiece is inserted fully into the vault.…”
Section: Vulvovaginal Protocolmentioning
confidence: 99%
See 1 more Smart Citation