2021
DOI: 10.1117/1.jbo.26.3.036004
|View full text |Cite
|
Sign up to set email alerts
|

Focused x-ray luminescence imaging system for small animals based on a rotary gantry

Abstract: . Significance: The ability to detect and localize specific molecules through tissue is important for elucidating the molecular basis of disease and treatment. Unfortunately, most current molecular imaging tools in tissue either lack high spatial resolution (e.g., diffuse optical fluorescence tomography or positron emission tomography) or lack molecular sensitivity (e.g., micro-computed tomography, ). X-ray luminescence imaging emerged about 10 years ago to address this is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 25 publications
(40 reference statements)
0
5
0
Order By: Relevance
“…We are scanning both euthanize mice with inserted capillary tubes as targets and in vivo mice with tumor targets and the experimental results will be reported soon. We will also use the machine learning algorithms for better XLCT reconstruction and will apply the bright nanoparticle to save the measurement time further [11].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…We are scanning both euthanize mice with inserted capillary tubes as targets and in vivo mice with tumor targets and the experimental results will be reported soon. We will also use the machine learning algorithms for better XLCT reconstruction and will apply the bright nanoparticle to save the measurement time further [11].…”
Section: Discussionmentioning
confidence: 99%
“…A PMT (H8259-01, Hamamatsu) connected with the scintillator via light guide was also mounted on the gantry. We used a heavy-duty linear stage (NLS4-20-12, Newmark Systems Inc.) to translate the XOS X-ray tube at a high speed and a good position precision [11]. The heavy-duty linear stage was also mounted on the rotary gantry.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 3 shows photos of the XLCT imaging systems with two measurement fiber bunders. The XLCT imaging system has been described in other publications [6][7][8][9][10][11][12][13]. Briefly, an X-ray tube (X-Beam Powerflux [Mo anode], XOS) was operated at 30 KVp and 0.5 mA with the beam diameter of 100 m.…”
Section: Xlct Imaging System With Multichannel and Phantoms With Mult...mentioning
confidence: 99%
“…In this work, we proposed an imaging approach to measure the oxygenation concentration in deep tissues, based on the XLCT system [6][7][8][9][10][11][12][13], with the combined strengths of high measurement sensitivity and high spatial resolution. The proposed method measures the oxygen concentration by exciting X-ray scintillators which emits optical photons to excite oxygen-dependent phosphorescence dyes [14].…”
Section: Introductionmentioning
confidence: 99%