2021
DOI: 10.1107/s1600577520016173
|View full text |Cite
|
Sign up to set email alerts
|

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Abstract: Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
28
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
2
1

Relationship

4
5

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 83 publications
0
28
0
Order By: Relevance
“…X-ray data were collected at the National Synchrotron Light Source II (NSLS-II) beamline 17-ID-2 (FMX) (Schneider et al, 2021) using an X-ray beam of energy 12.66 keV, corresponding to a wavelength of 0.9793 Å; a horizontal-bounce Si111 double crystal monochromator; and an Eiger X 16M pixel array detector (Dectris). Temperature at the sample goniometer was controlled using a Cryostream 800 (OxfordCryosystems).…”
Section: Crystal Harvesting and X-ray Data Collectionmentioning
confidence: 99%
“…X-ray data were collected at the National Synchrotron Light Source II (NSLS-II) beamline 17-ID-2 (FMX) (Schneider et al, 2021) using an X-ray beam of energy 12.66 keV, corresponding to a wavelength of 0.9793 Å; a horizontal-bounce Si111 double crystal monochromator; and an Eiger X 16M pixel array detector (Dectris). Temperature at the sample goniometer was controlled using a Cryostream 800 (OxfordCryosystems).…”
Section: Crystal Harvesting and X-ray Data Collectionmentioning
confidence: 99%
“…The implementation of the Jlib system, from the robot task layer written in the VAL3 language (Stä ubli, Switzerland), up to the included 'EMBL' EPICS-based input-output controller (IOC) have been implemented as described by Papp, Felisaz et al (2017). Both the LiX Bluesky server (https://nsls-ii.github.io/bluesky/) and AMX/FMX Life Science Data Collection (LSDC) server (Schneider et al, 2021) interface with the robot control system via a Python (Van Rossum & Drake, 2009) based robot control library customized for each beamline, which provides both control of and feedback from the robot system.…”
Section: Robot Control Software Architecturementioning
confidence: 99%
“…The Advanced Beamlines for Biological Investigations using X-rays project, which was funded by the National Institutes of Health, constructed two MX beamlines and one bioSAXS beamline: the highly Automated Macromolecular Crystallography beamline (AMX; https://www.bnl. gov/nsls2/beamlines/beamline.php?r=17-ID-1), the Frontier Macromolecular Crystallography beamline (FMX; Schneider et al, 2021) and the Life Science X-ray scattering beamline (LiX; Yang et al, 2020). Due to the brightness of the National Synchrotron Light Source II (NSLS-II), these beamlines can achieve fluxes greater than 10 12 photons s À1 at the sample.…”
Section: Introductionmentioning
confidence: 99%
“…Diffraction data were collected at the NSLS-II beamline FMX (17ID-2) at 100 K (Fuchs et al ., 2016, Schneider et al ., 2021). The beamline is equipped with an Eiger 16M detector.…”
Section: Methodsmentioning
confidence: 99%