2013
DOI: 10.1002/ccd.25229
|View full text |Cite
|
Sign up to set email alerts
|

Fluoroscopy‐guided snare retrieval of the celt ACD® metallic vascular closure device following failed deployment

Abstract: We report a case of endovascular snare retrieval of a new stainless steel vascular closure device (Celt ACD(®) , Kimal, Middlesex, UK) from the common femoral artery, following device failure after diagnostic coronary angiography. The stainless steel composition of the device aided successful fluoroscopic localization and removal.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…However, cases of successful retrieval of embolised Angio-Seal® devices through endovascular approaches have been reported (Suri et al 2015; Jud et al 2017). The successful endovascular retrieval of a distally embolised Celt ACD®, following primary device failure, was reported by Cahill et al (Cahill et al 2013). The device was visualised fluoroscopically and found to be situated in the common femoral artery.…”
Section: Discussionmentioning
confidence: 86%
“…However, cases of successful retrieval of embolised Angio-Seal® devices through endovascular approaches have been reported (Suri et al 2015; Jud et al 2017). The successful endovascular retrieval of a distally embolised Celt ACD®, following primary device failure, was reported by Cahill et al (Cahill et al 2013). The device was visualised fluoroscopically and found to be situated in the common femoral artery.…”
Section: Discussionmentioning
confidence: 86%
“…The endoluminally-anchored part of the implant poses the risk of intravascular device migration with luminal obstruction and flow limitation. [16][17][18] Furthermore, the device proved inapplicable in acute vascular access angles between 70° and 90°, occurring in antegrade approaches. Thus, we suggest ultrasound guidance for the initial antegrade puncture, in order to achieve an access angle of less than 50°.…”
Section: Discussionmentioning
confidence: 99%
“…A standard conventional surgical embolectomy has been traditionally performed to manage distal device embolization [ 7 , 8 ]. However, more recent endovascular approaches have challenged the traditional surgical approach, with promising results being reported [ 5 , 9 , 10 ].…”
Section: Discussionmentioning
confidence: 99%