1989
DOI: 10.1039/an9891400843
|View full text |Cite
|
Sign up to set email alerts
|

Flow injection sample-to-standard additions method. Spectrophotometric determination of hydrochloric acid and orthophosphate

Abstract: Conventional flow injection (FI) has been utilised for the development of the sample-to-standard additions method as an alternative to the reverse FI standard additions method. An equation has been derived for the proposed method, allowing the calculation of sample concentration from two transient signals obtained from the injection of the sample solution and the blank, which must possess matched matrix composition. For these conditions the sample-to-standard additions method was as effective as the standard … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0

Year Published

1993
1993
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…Recently, Campõ¨ns-Falco¨et al [48] compared the performance of diå erent approaches [35, 36, 38± 40] for standard addition in FIA and Lavilla et al [49] studied the applicability of the method proposed by Israel and Barnes [39] with and without the use of a matrixmatched blank for determination of metals in sewage sludge.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Recently, Campõ¨ns-Falco¨et al [48] compared the performance of diå erent approaches [35, 36, 38± 40] for standard addition in FIA and Lavilla et al [49] studied the applicability of the method proposed by Israel and Barnes [39] with and without the use of a matrixmatched blank for determination of metals in sewage sludge.…”
Section: Introductionmentioning
confidence: 99%
“…In 1989, Israel and Barnes [39] developed a sample-tostandard addition method also based on two injections, blank and sample, which showed the disadvantag e of matching matrix composition into standard carrier composition. Beuchemin [40] employed a variation of the method proposed by Israel and Barnes [39] for ICP-MS.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Such problems have been circumvented by using automated flow systems. [7][8][9][10][11][12][13][14][15][16][17][18][19] Versatile and flexible flow-batch approaches [20][21][22][23] have been proposed to automate some analytical systems, as developed by our research group. The flow-batch systems use three-way solenoids valves and an open mixing chamber and are characterised to combine the intrinsic favorable features of both the flow and batch techniques and to provide very good analytical figures of merit.…”
Section: Introductionmentioning
confidence: 99%