2006
DOI: 10.1016/j.talanta.2005.10.018
|View full text |Cite
|
Sign up to set email alerts
|

Flow injection potentiometric determination of clobutinol hydrochloride

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 18 publications
0
6
0
Order By: Relevance
“…To calculate the temperature coefficient of the cell and the standard cell potentials, , were determined at different temperatures from the respective calibration plots as the intercept of these plots at-log [Ser-Cl, mol L −1 ] = 0, [46,47] . The values of and are 3.70 × 10 −4 and 4.50 × 10 −4 , 3.19 × 10 −3 and 3.69 × 10 −3 , and 4.52 × 10 −3 and 3.79 × 10 −3 V/°C for Ser-PM, Ser-SM, and Ser-ST sensors, respectively, Fig.…”
Section: Resultsmentioning
confidence: 99%
“…To calculate the temperature coefficient of the cell and the standard cell potentials, , were determined at different temperatures from the respective calibration plots as the intercept of these plots at-log [Ser-Cl, mol L −1 ] = 0, [46,47] . The values of and are 3.70 × 10 −4 and 4.50 × 10 −4 , 3.19 × 10 −3 and 3.69 × 10 −3 , and 4.52 × 10 −3 and 3.79 × 10 −3 V/°C for Ser-PM, Ser-SM, and Ser-ST sensors, respectively, Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The flow injection setup is that previously reported, 21,22) Fig. 1 represents the schematic diagram of the flow injection system used in the measurements.…”
Section: Methodsmentioning
confidence: 99%
“…A saturated calomel electrode (SCE) was used as the external reference, while a Ag/AgCl wire was used as the internal reference electrode. The electrochemical system of the conventional electrode may be represented as follows: Panc-carbon paste electrode/test solution//KCl salt bridge//saturated calomel electrode.The flow injection setup is that previously reported, 21,22) Fig. 1 represents the schematic diagram of the flow injection system used in the measurements.…”
mentioning
confidence: 99%
“…Recently, a HPLC method to determine this drug together with some anti-inflammatory drugs in urine has been described (Malliou et al, 2004). A potentiometric ion-selective electrode method based on clobutinol-tetraphenyl borate has also been reported (Issa, Zayed, 2006). Doxylamine succinate, (DOX), chemically N,Ndimethyl-2- [-methyl-(2pyridyl)benzyloxy]ethylamine hydrogen succinate, is an antihistaminic with antimuscarinic and pronounced sedative effects.…”
Section: L O B U T I N O L H Y D R O C H L O R I D E ( C L O )mentioning
confidence: 99%