2010
DOI: 10.1002/elan.200900635
|View full text |Cite
|
Sign up to set email alerts
|

Flow Injection Analysis of Aluminum Chlorohydrate in Antiperspirant Deodorants Using a Built‐in Three‐in‐one Screen‐Printed Silver Electrode

Abstract: A screen-printed silver strip with a built-in three-in-one electrode (SPAgE) configuration of Ag-working, Ag-counter and Ag/Ag(x)O (silver oxides) pseudoreference electrodes has been developed for sensitive and selective electrochemical flow injection analysis (FIA) of aluminum chlorohydrate (ACH) present in antiperspirants, through the free Cl(-) ion liberated from ACH in aqueous medium, as a redox signal at Ag-working electrode in pH 6 phosphate buffer solution (PBS). The solution phase and instrumental para… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
3
0
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 16 publications
1
3
0
2
Order By: Relevance
“…By using a screen-printed silver electrode (SPAgE) in an FIA system, aluminum chlorohydrate (ACH) was determined in antiperspirant samples by monitoring the free Cl – ions liberated from ACH. The results obtained for four different real samples (with and without ACH content) were in good agreement with the product labels . An SPCE modified with silver microcubes was employed for the determination of nitrite in meat, and the results were consistent with the spectrometric method …”
Section: Flow Injection Analysis (Fia)supporting
confidence: 72%
See 1 more Smart Citation
“…By using a screen-printed silver electrode (SPAgE) in an FIA system, aluminum chlorohydrate (ACH) was determined in antiperspirant samples by monitoring the free Cl – ions liberated from ACH. The results obtained for four different real samples (with and without ACH content) were in good agreement with the product labels . An SPCE modified with silver microcubes was employed for the determination of nitrite in meat, and the results were consistent with the spectrometric method …”
Section: Flow Injection Analysis (Fia)supporting
confidence: 72%
“…The results obtained for four different real samples (with and without ACH content) were in good agreement with the product labels. 53 An SPCE modified with silver microcubes was employed for the determination of nitrite in meat, and the results were consistent with the spectrometric method. 54 SPCEs modified with copper have also been reported.…”
Section: Flow Injection Analysis (Fia)mentioning
confidence: 54%
“…Consequently, there is need for its determination of Al in such formulations. Chiu et al [104] have utilised a screen-printed silver sensor system as part of a flow injection system for its determination. The sensor consisted of Ag working and counter electrodes and a Ag/AgO reference electrode.…”
Section: Platinum Gold and Silver Screen-printed Carbon Electrodesmentioning
confidence: 99%
“…Diferentes células FIA adaptadas para o uso de SPEs tem sido propostas e versões comerciais podem ser encontradas na literatura e aplicadas para a análise de amostras farmacêuticas e ambientais (Bergamini et al, 2007;Chiu et al, 2010;Mozo et al, 2012;Salgado-Figueroa et al, 2013;. Bergamini et al (2007) desenvolveram uma metodologia para a determinação de procaína empregando SPE de carbono sem modificação em um sistema FIA com detecção amperométrica.…”
Section: Análise Por Injeção Em Fluxo (Fia)unclassified
“…O método descrito forneceu boa precisão (DPR = 3,2 %), limite de detecção de 6,0 µmol L -1 e frequência analítica de 36 injeções por hora. Chiu et al (2010) realizaram a determinação de cloridrato de alumínio em tampão fosfato 0,1 mol L -1 (pH = 6,0) utilizando o sistema FIA e SPE de prata, no qual o eletrodo de trabalho e contra eletrodo são de prata e um pseudo-referência de Ag/AgxO. Neste trabalho também obteve-se valores de precisão satisfatórios (DPR = 2,21 % e 2,16 % para concentrações de 5 e 50 ppm, respectivamente) e um limite de detecção de 295 ppb.…”
Section: Análise Por Injeção Em Fluxo (Fia)unclassified