FlavonQ: An Automated Data Processing Tool for Profiling Flavone and Flavonol Glycosides with Ultra-High-Performance Liquid Chromatography–Diode Array Detection–High Resolution Accurate Mass–Mass Spectrometry

Abstract: Profiling flavonoids in natural products poses a great challenge due to the diversity of flavonoids, the lack of commercially available standards, and the complexity of plant matrixes. The increasingly popular use of ultra-high-performance liquid chromatography-diode array detection-high resolution accurate mass-mass spectrometry (UHPLC-HRAM-MS) for the analysis of flavonoids has provided more definitive information but also vastly increased amounts of data. Thus, mining of the UHPLC-HRAM-MS data is a very dau… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
28
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 27 publications
(29 citation statements)
references
References 29 publications
(60 reference statements)
1
28
0
Order By: Relevance
“…Persimmon leaves are known to contain high levels of flavone and flavonol glycosides, which have characteristic UV-Vis absorbance at around 354 nm 19 ; therefore 354 nm was used as the main acquisition wavelength in the UHPLC-PDA analysis. Eight flavone and flavonol glycoside reference standards and the PLF extract was analyzed by using UHPLC-PDA-ESI/MS n method, and their representative UV-Vis chromatograms at 354 nm are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Persimmon leaves are known to contain high levels of flavone and flavonol glycosides, which have characteristic UV-Vis absorbance at around 354 nm 19 ; therefore 354 nm was used as the main acquisition wavelength in the UHPLC-PDA analysis. Eight flavone and flavonol glycoside reference standards and the PLF extract was analyzed by using UHPLC-PDA-ESI/MS n method, and their representative UV-Vis chromatograms at 354 nm are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The computer program used for data processing in this work was developed based on FlavonQ (Zhang et al, 2015). …”
Section: Resultsmentioning
confidence: 99%
“…Each UV-vis spectrum was normalized to unit vector length before the comparison (Zhang and Harrington, 2013, 2015). The comparison is expressed by the Pearson product-moment correlation coefficient (Zhang et al, 2015). The non-PA peaks are eliminated by a user-adjustable threshold for the similarity analysis.…”
Section: Resultsmentioning
confidence: 99%
“…to transform time of flight spectrum to mass spectrum to use m/z ratio for further spectral analysis [25]. For calibration, the user has to select two known peaks (H + and C + or CH 3 + peaks) to calculate constant a and b to convert all time points to m/z ratio.…”
Section: Resultsmentioning
confidence: 99%