2011
DOI: 10.1080/10255842.2010.482044
|View full text |Cite
|
Sign up to set email alerts
|

Fit optimisation of a distal medial tibia plate

Abstract: An iterative method for the fit optimisation of a pre-contoured fracture fixation plate for a given bone data set is presented. Both plate shape optimisation and plate fit quantification are conducted in a virtual environment utilising computer graphical methods and 3D bone and plate models. Two optimised shapes of the undersurface of an existing distal medial tibia plate were generated based on a dataset of 45 3D bone models reconstructed from computed tomography image data of Japanese tibiae. The existing pl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
28
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 25 publications
(39 citation statements)
references
References 21 publications
0
28
0
1
Order By: Relevance
“…Im Rahmen der weiteren wissenschaftlichen Analyse müssen Faktoren wie Pseudarthroserate, funktionelle Ergebnisse, Schmerz-Scores, Lebensqualität und kosmetische Aspekte berücksichtigt werden [23]. In der Vergangenheit hat sich bei anatomisch vorgeformten Implantaten im Bereich der Tibia eine hohe Passungenauigkeit gezeigt [5,18]. Auch bei den hier untersuchten Klavikulaplatten zeigte sich, dass sich diese hohe Passgenauigkeit auch bei randomisiert ausge- Plate fit of a novel clavicula plate system (VariAx Clavicle) developed using a CT-based anatomical bone database compared to reconstruction plates individually formed by surgeons Abstract Background.…”
Section: Diskussionunclassified
“…Im Rahmen der weiteren wissenschaftlichen Analyse müssen Faktoren wie Pseudarthroserate, funktionelle Ergebnisse, Schmerz-Scores, Lebensqualität und kosmetische Aspekte berücksichtigt werden [23]. In der Vergangenheit hat sich bei anatomisch vorgeformten Implantaten im Bereich der Tibia eine hohe Passungenauigkeit gezeigt [5,18]. Auch bei den hier untersuchten Klavikulaplatten zeigte sich, dass sich diese hohe Passgenauigkeit auch bei randomisiert ausge- Plate fit of a novel clavicula plate system (VariAx Clavicle) developed using a CT-based anatomical bone database compared to reconstruction plates individually formed by surgeons Abstract Background.…”
Section: Diskussionunclassified
“…With regard to aspects related to the surgical procedure itself, use of anatomically enhanced plate designs may allow for increased opportunities for the use of minimally invasive operative techniques . Furthermore, such plates require little to no intra‐operative bending, which is advantageous as bending has the potential to decrease the mechanical stability of the plate, which may result in an increased risk of implant failure . Additionally, a well‐shaped plate can be used as a template to realign the fracture parts prior to surgical fixation …”
mentioning
confidence: 99%
“…Furthermore, such plates require little to no intra‐operative bending, which is advantageous as bending has the potential to decrease the mechanical stability of the plate, which may result in an increased risk of implant failure . Additionally, a well‐shaped plate can be used as a template to realign the fracture parts prior to surgical fixation .…”
mentioning
confidence: 99%
See 2 more Smart Citations