2018
DOI: 10.1016/j.nima.2018.05.043
|View full text |Cite
|
Sign up to set email alerts
|

Fission fragment velocity distribution measurement using time of flight technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 22 publications
1
3
0
Order By: Relevance
“…The timing resolution thus obtained was σ = 230 (10) ps [figure 4(c)] in contrast to 205(6) ps obtained using analog instrumentation. The above values compare well with previously reported ones using BaF 2 and BC501A scintillation detectors [20][21][22][23]. This demonstrated the utility of the digitizer for fast-timing measurements as well.…”
Section: Coincidence Measurementssupporting
confidence: 90%
“…The timing resolution thus obtained was σ = 230 (10) ps [figure 4(c)] in contrast to 205(6) ps obtained using analog instrumentation. The above values compare well with previously reported ones using BaF 2 and BC501A scintillation detectors [20][21][22][23]. This demonstrated the utility of the digitizer for fast-timing measurements as well.…”
Section: Coincidence Measurementssupporting
confidence: 90%
“…There are several available techniques to estimate experimentally the relative isotopic yield distribution of fission fragments. In the case of 235 U(nth, f ) fission reaction, such studies have already been carried out using recoil mass separators, time-of-flight measurements using multiwire proportional counter (MWPC) and radiochemical analysis [20][21][22][23][24]. It is to be pointed out here that the majority of the previous investigations were aimed for extracting the yields of the isotopes belonging to the lighter fragment region.…”
Section: Introductionmentioning
confidence: 99%
“…There are several available techniques to estimate experimentally the relative isotopic yield distribution of fission fragments. In the case of 235 U(n th ,f ) fission reaction, such studies have already been carried out using recoil mass separators, time-of-flight measurements using MWPCs (Multi Wire Proportional Counter) and radiochemical analysis [20][21][22][23][24]. It is to be pointed out here that the majority of the previous investigations were aimed for extracting the yields of the isotopes belonging to the lighter fragment region.…”
Section: Introductionmentioning
confidence: 99%