First Experiences With a New Adjustable Plate for Osteosynthesis of Scaphoid Nonunions

Abstract: Scaphoid plate osteosynthesis should be regarded as a salvage procedure, and the indication for the procedure should be established accordingly. It is a simple procedure in terms of technique. The plate can be adjusted very well to the anatomic shape of the scaphoid, and one can achieve a high degree of stability, particularly rotational stability.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
26
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(31 citation statements)
references
References 21 publications
0
26
0
1
Order By: Relevance
“…Leixnering et al treated 6 patients with scaphoid nonunions who had previously undergone screw fixation with plate osteosynthesis and reported 100% union rate at an average of 5 months. 32 The most significant weakness of our study was the small sample size, limiting the power of our results. The retrospective nature and lack of controls also potentially introduces bias.…”
Section: Discussionmentioning
confidence: 92%
“…Leixnering et al treated 6 patients with scaphoid nonunions who had previously undergone screw fixation with plate osteosynthesis and reported 100% union rate at an average of 5 months. 32 The most significant weakness of our study was the small sample size, limiting the power of our results. The retrospective nature and lack of controls also potentially introduces bias.…”
Section: Discussionmentioning
confidence: 92%
“…14 However, poorer outcomes have been reported with grip strength of 30 kg, or only 55% of the unaffected side. 15 Clinical symptoms have included clicking, cold intolerance, or aching 9 or pain on open palm push-ups. 14 We had one case of radioscaphoid arthritis-mainly affecting the radial styloid.…”
Section: Discussionmentioning
confidence: 99%
“…7 The plate can press on corticocancellous graft and prevent it from displacing. 8 It has been used in nonunions, 9 comminuted fracutures, 10 and with vascularized grafts. 11 As this is a relatively new technique, small series in the literature have been published.…”
mentioning
confidence: 99%
“…Thirty-four cases of volar plate fixation of scaphoid nonunion with vascularized or iliac crest bone graft have been described among Dodds et al, Ghoneim, and Leixnering et al Those authors report two failed union among these 34 cases. 5,12,13 For biomechanical reasons alone, the authors propose that locking plate fixation should be considered at least equivalent to screw fixation for scaphoid nonunion. Based on the superior performance of locking plates in simulated osteoporotic bone, and other clinical considerations, the authors believe that locking plate fixation merits consideration in cases of scaphoid nonunion with segmental defect.…”
Section: Discussionmentioning