2014
DOI: 10.1016/j.knee.2013.03.006
|View full text |Cite
|
Sign up to set email alerts
|

Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
30
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(34 citation statements)
references
References 37 publications
3
30
0
1
Order By: Relevance
“…This criterion was widely adopted for biomechanical analysis (Chen et al, 2014;Liang et al, 2011;Ni et al, 2015;Niu et al, 2014;Tupis et al, 2012). Our simulation showed that the maximum stress exerted on the metallic and absorbable screws was less than the bending strength and shear strength of titanium and PLLA (Chen et al, 2014;Fu et al, 2013;van Dijk et al, 2002). All fixations that we studied were sufficiently stable for treating calcaneal fracture and patients who have these fixations should be encouraged to begin early rehabilitation after surgery.…”
Section: Discussionmentioning
confidence: 74%
See 2 more Smart Citations
“…This criterion was widely adopted for biomechanical analysis (Chen et al, 2014;Liang et al, 2011;Ni et al, 2015;Niu et al, 2014;Tupis et al, 2012). Our simulation showed that the maximum stress exerted on the metallic and absorbable screws was less than the bending strength and shear strength of titanium and PLLA (Chen et al, 2014;Fu et al, 2013;van Dijk et al, 2002). All fixations that we studied were sufficiently stable for treating calcaneal fracture and patients who have these fixations should be encouraged to begin early rehabilitation after surgery.…”
Section: Discussionmentioning
confidence: 74%
“…Tetrahedral C3D4 elements were used to mesh the model. The calcaneus and the implants were assumed isotropic and linear elastic materials and their material properties, determined in previous reports (Ni et al, 2015;Chen et al, 2014;Moon et al, 2005), are listed in Table 2.…”
Section: Finite-element Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…Fifth, although the shape and thickness of osteoporotic bone are very different to those of normal bone, we created the osteoporotic model only by changing the elastic modulus of the tissue, not by adjusting the shape or thickness. This is similar to the method used in previous research [2325], and this method can still provide much information related to osteoporotic bone. Sixth, this study only evaluated early postoperative stability, without determining long-term biomechanical stabilization.…”
Section: Discussionmentioning
confidence: 52%
“…However the main challenges with this technique is the knee pain and union which take longer time as compared to mid shaft fractures. 8 Knee pain with this technique is common because of the reaming, surgical dissection and fracture in distal half. Younger age appeared to be a risk factor for knee pain.…”
Section: Introductionmentioning
confidence: 99%