2013
DOI: 10.1504/ijbet.2013.053712
|View full text |Cite
|
Sign up to set email alerts
|

Finite element analysis of different contact bearing couples for human hip prosthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
13
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 29 publications
2
13
0
Order By: Relevance
“…30 CF/PEEK is a thermoplastic semicrystalline polymer in the polyethereterketone (PEEK) family with excellent mechanical and chemical resistance properties. The properties of 30 CF/PEEK in terms of strength and stiffness can increase by introducing continuous fibers at high concentrations depending on a medical application [ 11 ]. Because of its high tensile strength and stiffness of the material, 30 CF/PEEK can replace UHMWPE acetabular cups in orthopedic applications.…”
Section: Methodsmentioning
confidence: 99%
“…30 CF/PEEK is a thermoplastic semicrystalline polymer in the polyethereterketone (PEEK) family with excellent mechanical and chemical resistance properties. The properties of 30 CF/PEEK in terms of strength and stiffness can increase by introducing continuous fibers at high concentrations depending on a medical application [ 11 ]. Because of its high tensile strength and stiffness of the material, 30 CF/PEEK can replace UHMWPE acetabular cups in orthopedic applications.…”
Section: Methodsmentioning
confidence: 99%
“…Quasi-static estimation of hip joint loading [8] In the cycle of movement, it is a substantial change -1.45 ≤ ≥ 4.4 (Fig. 3).…”
Section: Figurementioning
confidence: 99%
“…However, according to the scholarly work [8]and the original authors method for the endoprosthesis CoCrMo -PE-UHMW, if N = 2500 N, D2 = 32 mm,  = 0.098 mm the pressures are identical -10.2 MPa.…”
Section: Numerical Solution Of the Problemmentioning
confidence: 99%
“…Enhanced bearing longevity can be expected provided an adherent defect free coating is achieved; and the elastic moduli of the substrate and coating are reasonably matched [148]. From another perspective, rigorous mechanical models (as well as market trends) suggest the use of dissimilar bearing materials in lieu of hard-on-hard devices (i.e., CoP vs. CoC) [149][150][151]. Due to differences in chemical affinities, elastic moduli, and hardness, Si 3 N 4 -on-XLPE bearings should not experience the same slip-stick behavior that was observed in the Si 3 N 4 -on-Si 3 N 4 couples, although additional simulator testing needs to confirm this supposition.…”
Section: Swm Ceramic-on-ceramic Hip Simulator Studymentioning
confidence: 99%