Abstract: Three comparisons of ac–dc voltage transfer difference held from January to December 2004 are reported. Six NMIs in the SIM region took part: NRC (Canada), NIST (United States of America), CENAM (Mexico), INTI (Argentina), UTE (Uruguay) and INMETRO (Brazil).The comparisons were proposed to assess the measurement capabilities in ac–dc voltage transfer difference of the NMIs in the SIM region. The test points were selected to link the results with the equivalent CCEM Key Comparisons, through three NMIs participa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…a at 1 kHz, 20 kHz, 100 kHz, and 1 MHz with using a method similar to that used to linking EUROMET.EM-K6.a to CCEM-K6.a, SIM.EM-K6.a to CCEM-K6.a, and APMP.EM-K6.a to CCEM-K6.a, SIM.EM-K6.1 to CCEM-K6.a [9][10][11][12].…”
Section: Proposed Linking Key Comparisons Proceduresmentioning
confidence: 99%
“…a at 1 kHz, 20 kHz, 100 kHz, and 1 MHz with using a method similar to that used to linking EUROMET.EM-K6.a to CCEM-K6.a, SIM.EM-K6.a to CCEM-K6.a, and APMP.EM-K6.a to CCEM-K6.a, SIM.EM-K6.1 to CCEM-K6.a [9][10][11][12].…”
Section: Proposed Linking Key Comparisons Proceduresmentioning
confidence: 99%
“…We propose that the results COOMET.EM-K6a be linked to CCEM-K6aat 1 kHz, 20 kHz, 100 kHz, and 1 MHz with using a method similar to that used to linking EUROMET.EM-K6a to CCEM-K6a, SIM.EM-K6a to CCEM-K6a, and APMP.EM-K6a to CCEM-K6a, SIM.EM-K6.1to CCEM-K6a [2][3][4][5].…”
Section: Proposal For Linking To Ccem-k6a Key Comparison and Degrees mentioning
confidence: 99%
“…The contribution of this work to the body of instrumentation and measurement science is proposing the analytical description of the current distribution at the stages of determining the AC-DC transfer difference of the tested shunt. In particular, a vector diagram was composed for the case of applying the AC-DC transfer standard Fluke 792A used in national metrology institutes [10]- [13] and other leading calibrat ion and measuring laboratories .…”
Section: Introductionmentioning