Abstract:List of participating NMIs, countries and regional organizations is show in Table 1. Table 1 List of participating NMIs, countries and regional organizations NMI Country Regional organization
“…KV of COOMET.EM-K6.a of AC/DC voltage transfer of AC voltage of 3 V at frequency of 20 kHz is X KV = À2.0 μV/V, and corresponding combined standard uncertainty is u(X KV ) = 1.9 μV/V (k = 2 for coverage level of 0.95). DoE for NMI/DI participants of COOMET.EM-K6.a comparison for AC voltage of 3 V at frequency of 20 kHz [19] is shown in Figure 6.…”
Section: The Data Evaluation Of Standard Comparisonsmentioning
The international agreements are the basis for establishing the global metrological traceability at different measurement levels. The concepts and concept relations around metrological traceability are presented. An important element of providing the metrological traceability is the evaluation of measurement uncertainty. The procedure of linking of key and supplementary comparison results is described. Linking of key and supplementary comparison results of the Regional Metrology Organization for some quantities according to the described procedure was presented. Results for all participants of presented key and supplementary comparisons are satisfactory for chi-square test and E n number. The procedure of linking of key or supplementary comparison and national inter-laboratory comparison results is described. This procedure can be used for practical evaluation of specific interlaboratory comparison results on a national level in different countries by means of laboratory results of the National Metrology Institute and Designated Institute. This procedure can contribute the mutual recognition of measurement and testing results by different countries. Linking of key comparison and inter-laboratory comparison results for some quantities according to the described procedure was presented. Results for all participants of presented key comparison and interlaboratory comparison are satisfactory for chi-square test, E n number, z scores and ζ scores.
“…KV of COOMET.EM-K6.a of AC/DC voltage transfer of AC voltage of 3 V at frequency of 20 kHz is X KV = À2.0 μV/V, and corresponding combined standard uncertainty is u(X KV ) = 1.9 μV/V (k = 2 for coverage level of 0.95). DoE for NMI/DI participants of COOMET.EM-K6.a comparison for AC voltage of 3 V at frequency of 20 kHz [19] is shown in Figure 6.…”
Section: The Data Evaluation Of Standard Comparisonsmentioning
The international agreements are the basis for establishing the global metrological traceability at different measurement levels. The concepts and concept relations around metrological traceability are presented. An important element of providing the metrological traceability is the evaluation of measurement uncertainty. The procedure of linking of key and supplementary comparison results is described. Linking of key and supplementary comparison results of the Regional Metrology Organization for some quantities according to the described procedure was presented. Results for all participants of presented key and supplementary comparisons are satisfactory for chi-square test and E n number. The procedure of linking of key or supplementary comparison and national inter-laboratory comparison results is described. This procedure can be used for practical evaluation of specific interlaboratory comparison results on a national level in different countries by means of laboratory results of the National Metrology Institute and Designated Institute. This procedure can contribute the mutual recognition of measurement and testing results by different countries. Linking of key comparison and inter-laboratory comparison results for some quantities according to the described procedure was presented. Results for all participants of presented key comparison and interlaboratory comparison are satisfactory for chi-square test, E n number, z scores and ζ scores.
“…The coaxial connector for input voltage of the traveling standard П=ТЭ-6А is completed by detachable adapter in order to provide adaptation to usual connector N-type (female) [4].…”
Section: Travelling Standards For Comparisonsmentioning
confidence: 99%
“…Proposed to link the results from COOMET.EM-K6.a [4] to the CCEM-K6.a [5] which carried out between 1993 and 1999. VNIIM (Russia) is linking NMI as far as they participated in CCEM-K6.a.…”
“…The degree of equivalence D i of AC/DC voltage transfer references and its expanded uncertainty U(D i ) that participated in COOMET.EM-K6.a [4] and COOMET. EM-S1 [6] comparisons are shown in Table 5 for frequencies 1 kHz; 20 kHz; 100 kHz; 1 MHz.…”
Section: Proposed Linking Key and Supplementary Comparisons Proceduresmentioning
confidence: 99%
“…The proposed procedures linking of results of KCs CC of electric and magnetism (CCEM) and RMO of AC/DC voltage transfer references (COOMET.EM-K6.a [4] to CCEM-K6.a [5]), and key and SCs of RMOs of AC/DC voltage transfer references (COOMET.EM-S1 [6] to COOMET.EM-K6.a) was realized with using results of linking NMI (VNIIM, Russia).…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.