2006
DOI: 10.1002/bit.21248
|View full text |Cite
|
Sign up to set email alerts
|

Fermentation process tracking through enhanced spectral calibration modeling

Abstract: The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
28
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(30 citation statements)
references
References 41 publications
(39 reference statements)
2
28
0
Order By: Relevance
“…The optimal wavelength intervals to build a model may not be the regions where the functional groups of a substance show the highest absorbance, because the signal of groups of different analytes may overlap. 50 Despite the ability of PLS to resolve that information, still a better solution may be to use a region where the signal is not necessarily the highest, but instead more specific. 50 As stated earlier, several computerized methods to select the optimal wavelength regions have been developed.…”
Section: 3352mentioning
confidence: 99%
See 2 more Smart Citations
“…The optimal wavelength intervals to build a model may not be the regions where the functional groups of a substance show the highest absorbance, because the signal of groups of different analytes may overlap. 50 Despite the ability of PLS to resolve that information, still a better solution may be to use a region where the signal is not necessarily the highest, but instead more specific. 50 As stated earlier, several computerized methods to select the optimal wavelength regions have been developed.…”
Section: 3352mentioning
confidence: 99%
“…The number of LVs of a PLS model is usually optimized (Figure 4) by performing a cross-validation and minimizing the corresponding standard error of cross-validation (SECV) or the root mean squared error of cross-validation (RMSECV). 7,15,21 Different pretreatments and wavelength interval selection methods are often tested 7,21,50 to find a chemometric model as robust as possible (i.e, with the minimum SEP or RMSEP).…”
Section: Development Of Calibration Modelsmentioning
confidence: 99%
See 1 more Smart Citation
“…It has been observed that this simple averaging rule can significantly improve the model accuracy and robustness in various applications [4,6,22,23].…”
Section: Combination Using Simple Averaging Rulementioning
confidence: 99%
“…the models that are sensitive (in terms of model parameters and predictive performance) to small changes in the training data. In practice, bagging has been applied to a large number of model structures, including regression trees [3], regression with variable selection [4] and neural networks [5,6].…”
Section: Introductionmentioning
confidence: 99%