2019
DOI: 10.1186/s13014-019-1435-5
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of hybrid TomoHelical- and TomoDirect-based volumetric gradient matching technique for total body irradiation

Abstract: Background: Tomotherapy-based total body irradiation (TBI) is performed using the headfirst position (HFP) and feet-first position (FFP) due to treatment length exceeding the 135 cm limit. To reduce the dosimetric variation at the match lines, we propose and verify a volumetric gradient matching technique (VGMT) by combining TomoHelical (TH) and TomoDirect (TD) modes. Methods: Two planning CT image sets were acquired with HFP and FFP using 15 × 55 × 18 cm 3 of solid water phantom. Planning target volume (PTV) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…Helical TomoTherapy for magna-field irradiation offers a high degree of conformity, homogeneity of target coverage dose and significant sparing of OAR with optimal treatment efficiency, without the need for multiple junctions. This is possibly the reason why several groups have extensively evaluated it for TBI and TMI/TMLI [8,[10][11][12][13][14][15]. Recently volumetric modulated arc therapy (VMAT) has also been evaluated in this setting to a reasonable success [16].…”
Section: Discussionmentioning
confidence: 99%
“…Helical TomoTherapy for magna-field irradiation offers a high degree of conformity, homogeneity of target coverage dose and significant sparing of OAR with optimal treatment efficiency, without the need for multiple junctions. This is possibly the reason why several groups have extensively evaluated it for TBI and TMI/TMLI [8,[10][11][12][13][14][15]. Recently volumetric modulated arc therapy (VMAT) has also been evaluated in this setting to a reasonable success [16].…”
Section: Discussionmentioning
confidence: 99%
“…We preferred HT for magna-field irradiation as it offers a high degree of conformity, homogeneity of target coverage dose and significant sparing of OAR with optimal treatment efficiency, without the need for multiple junctions. This is possibly the reason why several groups have extensively evaluated it for TBI and TMI/TMLI [8][9][10][11][12][13][14]. Recently VMAT has also been evaluated in this setting to a reasonable success [15,16].…”
Section: Discussionmentioning
confidence: 99%
“…Tomo‐Helical (TH) mode provides a continuous 360° beam that may result in optimal dose distribution and dose conformity. 19 The Tomo‐Direct (TD) mode is a non‐rotational treatment option of the Tomotherapy platform and provides treatment at predetermined angles with a fixed gantry. 20 , 21 TomoHDA provides faster and better dose distribution with the new technology IDMS (integrated data management system) with Precision Planning System.…”
Section: Introductionmentioning
confidence: 99%