Thoracic malignancies comprise some of the most common and deadly cancers. Immunotherapies have been proven to improve survival outcomes for patients with advanced non-small cell lung cancer (NSCLC) and show great potential for patients with other thoracic malignancies. Radiation therapy (RT), an established and effective treatment for thoracic cancers, has acted synergistically with immunotherapies in preclinical studies. Ongoing clinical trials are exploring the clinical benefits of combining RT with immunotherapies and the optimal manner in which to deliver these complementary treatments.
The aim of this study is to assess the suitability of 5 mm millennium multileaf collimator (MMLC) for volumetric‐modulated arc therapy (VMAT)‐based lung stereotactic body radiotherapy (SBRT). Thirty lung SBRT patient treatment plans along with their planning target volumes (ranging from 2.01 cc to 150.11 cc) were transferred to an inhomogeneous lung phantom and retrospectively planned using VMAT technique, along with the high definition multileaf collimator (HDMLC) and MMLC systems. The plans were evaluated using Radiation Therapy Oncology Group (RTOG‐0813) treatment planning criteria for target coverage, normal tissue sparing, and treatment efficiency for both the MMLC and HDMLC systems using flat and flattening filter‐free (FFF) photon beams. Irrespective of the target volumes, both the MLC systems were able to satisfy the RTOG‐0813 treatment planning criteria without having any major deviation. Dose conformity was marginally better with HDMLC. The average conformity index (CI) value was found to be 1.069±0.034 and 1.075±0.0380 for HDMLC and MMLC plans, respectively. For the 6 MV FFF beams, the plan was slightly more conformal, with the average CI values of 1.063±0.029 and 1.073±0.033 for the HDMLC and MMLC plans, respectively. The high dose spillage was the maximum for 2 cc volume set (3% for HDMLC and 3.1% for MMLC). In the case of low dose spillage, both the MLCs were within the protocol of no deviation, except for the 2 cc volume set. The results from this study revealed that VMAT‐based lung SBRT using 5 mm MMLC satisfies the RTOG‐0813 treatment planning criteria for the studied target size and shapes.PACS numbers: 87.53.Ly, 87.53D, 87.56.jk
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.