2023
DOI: 10.3390/su15021362
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility and Techno-Economic Evaluation of Hybrid Photovoltaic System: A Rural Healthcare Center in Bangladesh

Abstract: This study aimed to investigate a techno-economic evaluation of the photovoltaic system, along with a diesel generator as a backup supply, to ensure a continuous twenty-four hours power supply per day, no matter the status of the weather. Healthcare centers in Bangladesh play a vital role in the health issues of the residents of rural areas. In this regard, a healthcare center in Baliadangi—Lahiri Hat Rd, Baliadangi, Thakurgaon, Bangladesh, was selected to be electrically empowered. The simulation software Hyb… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…According to Ma and Javed, it is optimal to make hybrid system of RES [49]. Analysed RES types can be considered for RES microsystems and hybrid photovoltaic systems, which could be better in comparison to other energy sources [50,51]. To make an effective energy system, the combination of solar water heaters and smart buildings can be considered as well, as determined by Zening et al [52].…”
Section: Discussionmentioning
confidence: 99%
“…According to Ma and Javed, it is optimal to make hybrid system of RES [49]. Analysed RES types can be considered for RES microsystems and hybrid photovoltaic systems, which could be better in comparison to other energy sources [50,51]. To make an effective energy system, the combination of solar water heaters and smart buildings can be considered as well, as determined by Zening et al [52].…”
Section: Discussionmentioning
confidence: 99%
“…The COE is the mean cost of fruitful electrical energy per kWh, and is one of the most important parameters for comparing the cost effectiveness of hybrid systems and for finding the optimal size of the system [8][9][10]13,15,17,20,50].…”
Section: Net Present Cost-npcmentioning
confidence: 99%
“…Auto-sized generators uses diesel for designing a model. The diesel price is estimated at $0.872/liter [28] . As shown in Table 6, the component capital cost is $160 and replacement cost is $128 and the maintenance and operation cost is $0.01 per hour.…”
Section: Diesel Generatormentioning
confidence: 99%
“…The term payback period refers to the amount of time it takes to recover the cost of an investment. So, in this system total power generation is 53,736 kWh per year and the electricity cost is $0.97 per unit [28] .…”
Section: Payback Periodmentioning
confidence: 99%