Faulty Feeder Detection Based on Space Relative Distance for Compensated Distribution Network With IIDG Injections

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Note that, when a single-phase grounding fault occurs, the ASC and the proposed topology are immediately activated, so that the fault voltage can be well compensated, and the distribution system can be allowed to operate during the faulty period for 1-2 h, so the circuit breaker will not be tripped immediately [3,[10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26]. After a certain delay, the phase selection switch of the proposed topology trips.…”
Section: Costs Comparison With Existing Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Note that, when a single-phase grounding fault occurs, the ASC and the proposed topology are immediately activated, so that the fault voltage can be well compensated, and the distribution system can be allowed to operate during the faulty period for 1-2 h, so the circuit breaker will not be tripped immediately [3,[10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26]. After a certain delay, the phase selection switch of the proposed topology trips.…”
Section: Costs Comparison With Existing Methodsmentioning
confidence: 99%
“…The phase‐selection switch is used to select the fault phase and connect the antiphase transformer and the MSVR. The specific phase selection methods can be referred to in terms of studies on faulty phase selection [23–25]. Finally, the neutral point voltage can be adjusted to UN=Ej, which satisfies Equation (2), and thus the fault voltage is fully compensated.…”
Section: Principle Of Full Compensation For Single‐phase Grounding Faultmentioning
confidence: 99%
“…Most of the 3~66 kV power supply systems in China's petrochemical enterprises adopt neutral point non-effective grounding. Among them, due to the compensation effect of the arc suppression coil, the resonant grounding system has the disadvantages of the fault characteristic quantity not being obvious, and the fault detection being difficult after the single-phase grounding fault occurs [1][2][3][4][5], resulting in a worse faulty feeder detection effect [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the relationship among ride through time and short-circuit current is studied, and the short-circuit response of IIDG under different fault conditions was analyzed. In [17], a more accurate IIDG current estimation model based on the Gauss-Seidel method that considered the control strategy at the moment of fault was established. Moreover, the authors proposed a novel faulty feeder detection approach which used the zero-sequence current space relative distance.…”