2008
DOI: 10.1016/j.joen.2008.05.007
|View full text |Cite
|
Sign up to set email alerts
|

Fatigue Resistance of Engine-driven Rotary Nickel-Titanium Instruments Produced by New Manufacturing Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
315
2
11

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 315 publications
(338 citation statements)
references
References 26 publications
10
315
2
11
Order By: Relevance
“…However, the difference was not statistically significant (P > 0.05).The lower degree of changes in the angle and radius of curvature produced by TF could be attributed to the cervical pre-flaring, which reduces the instrument's friction with the root canal walls. In addition, the new manufacturing method of the TF instruments (R-phase heat treatment, twisting of the metal, and the surface deoxidation), resulting in increased phase transformation temperatures and increased flexibility of TF files compared with the other NiTi instruments manufactured by grinding as OS file instrument (4,6,19,(24)(25)(26) .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the difference was not statistically significant (P > 0.05).The lower degree of changes in the angle and radius of curvature produced by TF could be attributed to the cervical pre-flaring, which reduces the instrument's friction with the root canal walls. In addition, the new manufacturing method of the TF instruments (R-phase heat treatment, twisting of the metal, and the surface deoxidation), resulting in increased phase transformation temperatures and increased flexibility of TF files compared with the other NiTi instruments manufactured by grinding as OS file instrument (4,6,19,(24)(25)(26) .…”
Section: Discussionmentioning
confidence: 99%
“…It has a variable pitch that minimizes the "screw-in" effect and allows debris to be effectively channeled out of the canal (5) .Twisted File has been reported to be the most flexible instrument, with a significant improvement in flexibility ranging from 100% to 250%, which cut dentin efficiently with more uniform cutting, compared to machined nickeltitanium endodontic files (6,7) . Canal transportation and centering ratio has been evaluated in root canals with severe curvature and short radius using (TF), Pathfile-ProTaper (PP) and conventional stainless steel K-files.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, it might be assumed that the incidence of dentinal defects would be increased compared with preparations using full-sequence rotary systems [6][7][8][9][10].…”
Section: Brazilian Research Inmentioning
confidence: 99%
“…They are able to prepare canals with only one instrument, requiring less time than rotary full-sequence systems [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…[7][8][9][10] Many variables, such as the operational speed, the metal surface treatment and the metallurgic characterization of the NiTi alloys that could possibly influence the fatigue resistance of NiTi rotary files have been investigated. 11 Canal curvature is suspected to be the predominant risk factor for instrument failure because of flexural stresses and cyclic fatigue. 2,12,13 One additional factor potentially limiting resistance to fatigue fracture is corrosion that may occur in the presence of NaOCl solution.…”
Section: Introductionmentioning
confidence: 99%