2009
DOI: 10.4047/jkap.2009.47.4.424
|View full text |Cite
|
Sign up to set email alerts
|

Fatigue fracture of different dental implant system under cyclic loading

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The area mixed with plastic deformation surface and cleavage fracture area can be seen as semi-clevage 1,7) and it was well differentiated.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…The area mixed with plastic deformation surface and cleavage fracture area can be seen as semi-clevage 1,7) and it was well differentiated.…”
Section: Discussionmentioning
confidence: 98%
“…Therefore, the loosening by repeated loads 6) is divided into two steps: one step that causes the reduced full loads and extendibility due to minute slip between the thread of a screw by applying the external force such as masticatory force to screw binding site and the other step that occurs loosening caused by the reduced full loads to below the threshold when the thread of a screw is slightly rotating by the external force of vibration. Eventually, elongation and loosening of fixing screw and facture lead to the fracture of implant fixture [7][8][9] . There have been a lot of studies carried out on the loosening of implant by repeated loads and tightening and on fatigue fracture.…”
Section: Introductionmentioning
confidence: 99%
“…Patient was recalled for suture removal 1 week postoperatively. The RCTs w.r.t 11,12,13,14,22,23,33,34,35,42, and 44 were also carried out; 24 had to be extracted because of fracture during follow-up visits.…”
Section: Surgical Phasementioning
confidence: 99%
“…However, whether a cover screw is used or not, it does not have an influence on the osseointegration. 13 The most important characteristic feature of this implant system is its active resorbable blasting media (RBM) surface treatment with cutting edge, round apex dynamic body, thread abutment fixture connection, and taper design screw connection. The scanning electron microscopic roughness is 2.1 with a double 2.5 hexagon and the hexagon roughness value (Ra) of 1.2~1.8 µm.…”
Section: Figs 3a To H: Postoperative: (A and B) After Implant And Hea...mentioning
confidence: 99%