2005
DOI: 10.1109/tcapt.2004.838877
|View full text |Cite
|
Sign up to set email alerts
|

Fast Simulation of steady-state temperature distributions in electronic components using multidimensional model reduction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 17 publications
0
15
0
Order By: Relevance
“…-B = of (7) is "equivalent" to the Laplace variable s. Hence, the first idea explored by several groups [10] - [13] and based on generalization of moment matching, was to make multivariate expansions of (8) with respect to the Laplace variable s and parameters p i which are thus simultaneously preserved in symbolic form.…”
Section: Parametric Model Order Reductionmentioning
confidence: 99%
See 1 more Smart Citation
“…-B = of (7) is "equivalent" to the Laplace variable s. Hence, the first idea explored by several groups [10] - [13] and based on generalization of moment matching, was to make multivariate expansions of (8) with respect to the Laplace variable s and parameters p i which are thus simultaneously preserved in symbolic form.…”
Section: Parametric Model Order Reductionmentioning
confidence: 99%
“…We have used the multivariate-moment-matching approach from [13] and were able to reduce the time for transient integration of the FE model by a factor of 100. A parametric reduced model has only 117 degrees of freedom (DOF) but still provides high accuracy (see Fig.…”
Section: Parametric Model Order Reductionmentioning
confidence: 99%
“…We have used the multivariate-moment-matching approach from [9] and were able to reduce the time for transient integration of the FE model by a factor of 330. Parametric reduced models have only 60 degrees of freedom (DOF) but still provide high accuracy (see Figure 5).…”
Section: Parametric Model Order Reductionmentioning
confidence: 99%
“…By replacing a fully detailed thermal component model with a simplified one, simulation times can be greatly reduced. Depending on the procedure adopted, a replacement model can be in the form of a simple resistive network, such as a boundary condition independent compact thermal model [1]- [8], or in the form of a mathematical (reduced) model [9]- [11]. A significant amount of work has been done in developing methodologies to generate and construct these simplified models; however, their application in modeling a board-level environment has seen limited study [12].…”
Section: Introductionmentioning
confidence: 99%
“…In general, any linear component model can be described by the attachment (7), including boundary condition independent models created by a parametrized model reduction technique [11] or the use of an optimized compact model [22]- [24]. The use of these techniques would, however, introduce error into the component model itself which is undesirable for this work as the error due to the port configuration could not be isolated.…”
Section: Introductionmentioning
confidence: 99%