2022
DOI: 10.1002/rcm.9258
|View full text |Cite
|
Sign up to set email alerts
|

Fast pesticide analysis using low‐pressure gas chromatography paired with a triple quadrupole mass spectrometer equipped with short collision cell technology

Abstract: Rationale A proof of concept showing GC–MS/MS analysis time for pesticides can be dramatically reduced while maintaining a similar separation efficiency by combining a low‐pressure gas chromatography (LPGC) column with the enhanced selected reaction monitoring (SRM) switching speed of the short collision cell of a JEOL JMS‐TQ4000GC. Methods Triple‐quadrupole tandem mass spectrometry (standard EI + at 70 eV) was used to measure pesticides eluting from a low‐pressure gas chromatograph capillary column. Three tra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…While many parameters can be optimized to reduce the runtime (e.g., use of short columns, fast oven temperature ramps, or higher carrier-gas linear velocities), changing these parameters can lead to a loss of chromatographic resolution [93]. In this sense, low-pressure gas chromatography (LPGC)-MS has also been evaluated as an alternative to modifying the parameters of the method, avoiding the aforementioned disadvantages [94,95]. LPGC-MS is the most practical and beneficial fast GC technique available to achieve chromatographic separations in less than 10 min for applications that typically involve analysis times between 20 and 40 min [96].…”
Section: Chromatographic Separations In Ms-based Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…While many parameters can be optimized to reduce the runtime (e.g., use of short columns, fast oven temperature ramps, or higher carrier-gas linear velocities), changing these parameters can lead to a loss of chromatographic resolution [93]. In this sense, low-pressure gas chromatography (LPGC)-MS has also been evaluated as an alternative to modifying the parameters of the method, avoiding the aforementioned disadvantages [94,95]. LPGC-MS is the most practical and beneficial fast GC technique available to achieve chromatographic separations in less than 10 min for applications that typically involve analysis times between 20 and 40 min [96].…”
Section: Chromatographic Separations In Ms-based Methodsmentioning
confidence: 99%
“…For example, the determination of 244 pesticides in an 11 min run has been achieved using LPGC-QqQ-MS. This means a 50% decrease in analysis time compared to a traditional GC separation using a 30 m column [94]. Furthermore, the development and application of multidimensional GC has undoubtedly been a major trend in GC-MS methods in recent years, as it is a powerful tool to increase resolving power [97].…”
Section: Chromatographic Separations In Ms-based Methodsmentioning
confidence: 99%