2006
DOI: 10.1016/j.chroma.2005.10.071
|View full text |Cite
|
Sign up to set email alerts
|

Fast extraction, amplification and analysis of genes from human blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2006
2006
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 33 publications
0
4
0
1
Order By: Relevance
“…Recently, this commercial CE chip has been used for off-line detection of PCR products (10,11,13,16,69,73). Other microchip electrophoresis systems include the Hitachi SV 12-channel electrophoresis microchip (Hitachi Electronics Co.) (73), LabChip Õ 90 Automated Electrophoresis System (Caliper Lifesciences) (20) and CE chips with laserinduced fluorescence (LIF) detection (41,52,53,56). The off-line CE chip platform can offer walkaway and unattended analysis of DNA molecules, eliminate the time-consuming and messy slab gel process, generate much more reproducible and high quality data, and allow high-throughput laboratory analysis; however, the manual sample loading may increase the risk of cross contamination and the total analysis time.…”
Section: Off-line Detection Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, this commercial CE chip has been used for off-line detection of PCR products (10,11,13,16,69,73). Other microchip electrophoresis systems include the Hitachi SV 12-channel electrophoresis microchip (Hitachi Electronics Co.) (73), LabChip Õ 90 Automated Electrophoresis System (Caliper Lifesciences) (20) and CE chips with laserinduced fluorescence (LIF) detection (41,52,53,56). The off-line CE chip platform can offer walkaway and unattended analysis of DNA molecules, eliminate the time-consuming and messy slab gel process, generate much more reproducible and high quality data, and allow high-throughput laboratory analysis; however, the manual sample loading may increase the risk of cross contamination and the total analysis time.…”
Section: Off-line Detection Methodsmentioning
confidence: 99%
“…The static treatment involves the pre-coating of chip surface, during fabrication of PCR chip or immediately before use, with one of the following substances: SiO 2 (10,14,20,21,25), bovine serum albumin (BSA) (11,17,25,37,53,61,73), polyethylene glycol (PEG) (65,78,82) or silanizing agents (for example 3-glycidoxypropyl trimethoxysilane (11), dichlorodimethylsilane (23,69), Sigmacoat Õ (16,29) or trimethylchlorosilane (33). The SiO 2 pre-coating is a reproducible and inexpensive standard MEMS process and can be accomplished in a batch fashion.…”
Section: Surface Treatmentmentioning
confidence: 99%
See 1 more Smart Citation
“…In the years since its development, microchip capillary electrophoresis (CE) has established itself as an important research area in chemical and biochemical analysis. Many different applications have been demonstrated using this chemistry, including DNA sequencing and fragment analysis, proteomic separations, , and environmental analysis , to name a few. The great interest in microchip CE and microfluidics in general is due to the potential to generate complex chemical synthesizers and analyzers that provide the power of an entire chemical laboratory on a single chip .…”
mentioning
confidence: 99%
“…Μια άλλη ευρέως χρησιμοποιούμενη τεχνική είναι η τριχοειδής ηλεκτροφόρηση (CE) (Jorgenson JW, and Lukasc KD, 1983 (Poulsen CR, et al 2005;Hataoka Y, et al 20005;Lee JG, et al 2006). Άλλες CE ψηφίδες είναι η Hitachi 12-channel (Hitachi Electronics) (Zhang LH, et al 2006), LabChip" (Caliper Lifesciences) (Oh KW, et al 2006).…”
Section: μέθοδοι ανίχνευσηςunclassified