2021
DOI: 10.1007/s12161-021-01990-w
|View full text |Cite
|
Sign up to set email alerts
|

Fast Determination of Short-Chain Fatty Acids and Glucose Simultaneously by Ultraviolet/Visible and Refraction Index Detectors via High-Performance Liquid Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 16 publications
0
8
0
Order By: Relevance
“…LOD ranged from 4.0×10 −3 to 1.9×10 −2 μM, and LOQ ranged from 1.3×10 −2 to 6.2×10 −2 μM. Compared with the method reported previously (Table 2), the sensitivity of the method established in this study was much higher than the method with HPLC‐UV [26, 27, 29] and GC‐FID [30], and a little higher than the method with GC‐MS [24, 31] and HPLC‐MS [32]. The sensitivity was lower than the method with GC‐MS/MS [25], HPLC‐MS/MS [33, 34], and HPLC‐FLD [35], but our method was more universal and the cost of the instrument was much lower.…”
Section: Resultsmentioning
confidence: 54%
“…LOD ranged from 4.0×10 −3 to 1.9×10 −2 μM, and LOQ ranged from 1.3×10 −2 to 6.2×10 −2 μM. Compared with the method reported previously (Table 2), the sensitivity of the method established in this study was much higher than the method with HPLC‐UV [26, 27, 29] and GC‐FID [30], and a little higher than the method with GC‐MS [24, 31] and HPLC‐MS [32]. The sensitivity was lower than the method with GC‐MS/MS [25], HPLC‐MS/MS [33, 34], and HPLC‐FLD [35], but our method was more universal and the cost of the instrument was much lower.…”
Section: Resultsmentioning
confidence: 54%
“…One millilitre of sulfuric acid (1:1) was added to a 50-mL sample of ruminal fluid and stored at −20°C for subsequent analysis of N-NH 3 using the Kjeldahl methodology (Fenner 1965). Analysis of SCFA was performed using concentrated ruminal fluid samples, following Serafim et al (2021) methodology on a Shimadzu high-performance liquid chromatography system (model Prominence) equipped with an ultraviolet detector model SPD-20 and programmed to operate at a wavelength of 210 nm. The internal standard for the high-performance liquid chromatography was the crotonic acid.…”
Section: Ruminal and Blood Parametersmentioning
confidence: 99%
“…The injection volume was 20 µL. The quantified VFAs were acetate, propionate, and butyrate (mmol/L) [19].…”
Section: Ruminal Parametersmentioning
confidence: 99%