2016
DOI: 10.1039/c6ay00943c
|View full text |Cite
|
Sign up to set email alerts
|

Fast determination of diphenhydramine, pyridoxine, and 8-chlorotheophylline by capillary electrophoresis with capacitively coupled contactless conductivity detection

Abstract: This work reports a new and fast method for the simultaneous determination of diphenhydramine, pyridoxine, and 8-chlorotheophylline by CE-C4D.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 33 publications
(35 reference statements)
0
10
0
Order By: Relevance
“…A CE‐C 4 D method for simultaneous determination of diphenhydramine, pyridoxine and 8‐chlorotheophylline in pharmaceutical sample was described (Ribeiro, Freitas, Muñoz, Do Lago, & Richter, ). The separation of the three compounds was achieved in a BGE consisting of boric acid 20 mmol L −1 and sodium hydroxide at pH 9.0.…”
Section: Pharmaceutical Analysismentioning
confidence: 99%
“…A CE‐C 4 D method for simultaneous determination of diphenhydramine, pyridoxine and 8‐chlorotheophylline in pharmaceutical sample was described (Ribeiro, Freitas, Muñoz, Do Lago, & Richter, ). The separation of the three compounds was achieved in a BGE consisting of boric acid 20 mmol L −1 and sodium hydroxide at pH 9.0.…”
Section: Pharmaceutical Analysismentioning
confidence: 99%
“…Methods for determination of NH 4 + are mainly based on spectrophotometry [6][7][8], fluorometry [9], chemiluminescence [10,11], conductometry [12,13], potentiometry [14,15], and amperometry [16][17][18][19]. DIP is predominantly determined by LC [20][21][22][23][24], the most commonly employed technique for pharmaceuticals analysis, and some CE methods [25][26][27][28]. However, no analytical methods are described for simultaneous determination of these compounds.…”
Section: Introductionmentioning
confidence: 99%
“…C 4 D is constituted of two cylindrical electrodes situated around the capillary column without any direct contact with the electrolyte solution. It can be easily positioned anywhere along the capillary [27][28][29]. This system often offers short analysis time combined with low-cost, high separation efficiency and low consumption of reagents and samples [30].…”
Section: Introductionmentioning
confidence: 99%