2002
DOI: 10.1016/s0022-2836(02)00566-1
|View full text |Cite
|
Sign up to set email alerts
|

Fast Compaction of α-Lactalbumin During Folding Studied by Stopped-flow X-ray Scattering

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
103
0
3

Year Published

2004
2004
2010
2010

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 101 publications
(111 citation statements)
references
References 51 publications
5
103
0
3
Order By: Relevance
“…Scattering patterns were recorded by a CCD-based x-ray detector, which consisted of a beryllium-windowed x-ray image intensifier (Be-XRII) (V5445P-MOD, Hamamatsu Photonics, Hamamatsu, Japan), an optical lens, a CCD image sensor, and a data acquisition system (C7300, Hamamatsu Photonics), as described previously (32,33). The experimental details and the analyses of the scattering data were as described (32). Pair distribution (P(r)) functions were calculated using the GNOM program (34).…”
Section: Methodsmentioning
confidence: 99%
“…Scattering patterns were recorded by a CCD-based x-ray detector, which consisted of a beryllium-windowed x-ray image intensifier (Be-XRII) (V5445P-MOD, Hamamatsu Photonics, Hamamatsu, Japan), an optical lens, a CCD image sensor, and a data acquisition system (C7300, Hamamatsu Photonics), as described previously (32,33). The experimental details and the analyses of the scattering data were as described (32). Pair distribution (P(r)) functions were calculated using the GNOM program (34).…”
Section: Methodsmentioning
confidence: 99%
“…The experimental details and the analysis of the scattering data were essentially the same as described earlier (14). The sample solution in 1-mm path length mica-windowed cell was exposed to a monochromatic x-ray beam (1.5 Å).…”
Section: Methodsmentioning
confidence: 99%
“…The temperature of the sample solution was maintained at 25°C using a circulating water bath. Scattering patterns were recorded by a CCD-based x-ray detector, which consisted of a beryllium-windowed x-ray image intensifier (Be-XRII) (Hamamatsu, V5445P-MOD), an optical lens, a CCD image sensor, and a data acquisition system (Hamamatsu C7300) (14,15). The camera length was set to be 1485 or 2375 mm depending on the scattering-angle region to be observed.…”
Section: Methodsmentioning
confidence: 99%
“…I(0) decreases to the native level in the first phase, which suggests a decrease in the amount of hydrated waters in the transition from I 1 to I 2 (12,(35)(36)(37). I 2 possesses partial tertiary contacts demonstrated by the specific binding site for ANS and the increased Trp-4 fluorescence.…”
Section: L-shaped Conformational Landscape Of Smnmentioning
confidence: 98%