2006
DOI: 10.1002/jssc.200500430
|View full text |Cite
|
Sign up to set email alerts
|

Fast capillary GC using a low thermal mass column oven for the determination of residual solvents in pharmaceuticals

Abstract: A low thermal mass column oven was used for fast capillary GC analysis (high throughput) of residual solvents in pharmaceutical products. A dedicated capillary column, 20 m L x 180 microm ID x 1 microm DB-624 was programmed from 35 degrees C (30 s) to 150 degrees C at 100 degrees C/min and to 250 degrees C (30 s) at 200 degrees C/min, resulting in a total GC cycle time of less than 4 min. Complete separation of a target 20-component mixture was achieved, while method performance in terms of repeatability, sens… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…The static headspace GC is a conventional and powerful analytical technique that has been adopted and recommended by the European Pharmacopoeia and the United States Pharmacopoeia for the determination of residual solvents within quality control of pharmaceutical products . Relative simplicity of sample preparation, sensitivity and elimination of GC system contamination by unwanted non‐volatile substances belong to the main benefits of the headspace technique . However, analysis of some specific matrices for the RS content requires a special sample pretreatment.…”
Section: Introductionmentioning
confidence: 99%
“…The static headspace GC is a conventional and powerful analytical technique that has been adopted and recommended by the European Pharmacopoeia and the United States Pharmacopoeia for the determination of residual solvents within quality control of pharmaceutical products . Relative simplicity of sample preparation, sensitivity and elimination of GC system contamination by unwanted non‐volatile substances belong to the main benefits of the headspace technique . However, analysis of some specific matrices for the RS content requires a special sample pretreatment.…”
Section: Introductionmentioning
confidence: 99%
“…8 Among them, the most commonly used technique for the analysis of residual solvents is conventional gas chromatography (GC). 9,10 In order to analyze trace amounts of such analytes in pharmaceuticals, an appropriate sample preparation step is necessary prior to GC. 11,12 The traditional technique for residual solvent determination is direct injection; in which the drug substance or the formulation is dissolved in or extracted with a high boiling point solvent.…”
Section: Introductionmentioning
confidence: 99%