Fast and sensitive determination of 10 forbidden phthalates in perfumes by ultra–high performance liquid chromatography–electrospray ionization–tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…S is a coefficient related to the strength of a pure organic modifier in mobile phases and the molecular structure of an analyte; C water is the volumetric ratio of water in the mobile phase, which can be calculated as an integral value based on the instantaneous value of water ratio C water,t in an elution gradient setting; k b indicates the retention of a molecule using pure water as the mobile phase; and t R is the retention time.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…S is a coefficient related to the strength of a pure organic modifier in mobile phases and the molecular structure of an analyte; C water is the volumetric ratio of water in the mobile phase, which can be calculated as an integral value based on the instantaneous value of water ratio C water,t in an elution gradient setting; k b indicates the retention of a molecule using pure water as the mobile phase; and t R is the retention time.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, the serial gradients designed for Hela cell analysis started with the same mobile phase with low elution strength to hold the samples (i.e., RPLC started with 98% water for 2 min and HILIC started with 100% acetonitrile for 1.5 min, Figure S1 B and C). It may take some time for different LC gradients to condition the LC column and alter retention times of untargeted metabolites . By examining total ion currents (TICs) of analytical data, baselines were observed to increase after 5 min.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Spiked blank sample solution was prepared with blank sample solution to 1000 μg/L in the dark. A series of matrix calibration solutions (1,5,10,20,50, 100 μg/L) were freshly prepared by dilution of the spiked blank sample solution with blank sample solution.…”
Section: Preparation Of Matrix Calibration Solutionsmentioning
confidence: 99%
“…The risk compounds screened by the platform can further establish corresponding standard test methods, which can provide a technical basis for supervision. Conventional assay methods used in routine supervision include LC [1,2], GC [3], LC-MS/MS [4][5][6][7], and GC-MS/MS [8,9], which can accurately measure known cosmetic risk substances such as hormones [10,11], antibiotics [12,13], and other risky substances. However, conventional screening and detection methods need to be based on the information data of known risk substances.…”
Section: Introductionmentioning
confidence: 99%