2021
DOI: 10.1021/acs.analchem.1c01841
|View full text |Cite
|
Sign up to set email alerts
|

CRB-SWATH: A Method for Enhancing Untargeted Precursor Ion Extraction and Automatically Constructing Their Tandem Mass Spectra from SWATH Datasets by Chromatographic Retention Behaviors

Abstract: Sequential window acquisition of all theoretical spectra (SWATH) as a typical data-independent acquisition (DIA) strategy is favorable for untargeted metabolomics. It could theoretically acquire product ions of all precursor ions, including precursor ions showing chromatographic peaks of rather poor qualities. However, existing data processing methods present limited capabilities in capturing poor-quality peaks of precursor ions. Thus, although their product ions could be acquired, their precursor ions are abs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 32 publications
(55 reference statements)
0
10
0
Order By: Relevance
“…The typical base peak intensity (BPI) chromatograms of the QC sample are shown in Figure S1A and B. Based on the designed serial elution gradients (G1–G7, Figure S3), the dataset of QC was deconvoluted and extracted according to the previously mentioned CRB-SWATH protocol . Finally, 12 017 and 8805 peaks were found under positive and negative modes in the CRB-SWATH strategy, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The typical base peak intensity (BPI) chromatograms of the QC sample are shown in Figure S1A and B. Based on the designed serial elution gradients (G1–G7, Figure S3), the dataset of QC was deconvoluted and extracted according to the previously mentioned CRB-SWATH protocol . Finally, 12 017 and 8805 peaks were found under positive and negative modes in the CRB-SWATH strategy, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The fragmentation patterns of the mass spectra of the other metabolites were proposed (Figure S6–8). The raw files of the QC sample acquired via the CRB-SWATH approach were processed according to a previously described protocol . For targeted analysis, all scheduled MRM data were subjected to MultiQuant software (AB SCIEX, Concord, ON, Canada) and Microsoft Excel for peak integration, IS adjustment, and further data management.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations