2006
DOI: 10.1007/s10554-006-9098-3
|View full text |Cite
|
Sign up to set email alerts
|

Factors Affecting Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Myocardial Perfusion Single Photon Emission Computed Tomography

Abstract: The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were meas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…Infiltrative cardiac diseases such as ATTR-CM are often associated with extensive mid-wall fibrosis and left ventricular hypertrophy with subendocardial hypoperfusion [5,6]. The presence of myocardial fibrosis and reduced perfusion results in reduced tracer count, adding to the poor spatial and temporal resolution of MPI [7]. With poor LV border detection, LV size is overestimated and subsequent LVEF underestimated in MPI, as illustrated in our patient with ATTR-CM.…”
Section: Discussionmentioning
confidence: 84%
“…Infiltrative cardiac diseases such as ATTR-CM are often associated with extensive mid-wall fibrosis and left ventricular hypertrophy with subendocardial hypoperfusion [5,6]. The presence of myocardial fibrosis and reduced perfusion results in reduced tracer count, adding to the poor spatial and temporal resolution of MPI [7]. With poor LV border detection, LV size is overestimated and subsequent LVEF underestimated in MPI, as illustrated in our patient with ATTR-CM.…”
Section: Discussionmentioning
confidence: 84%
“…[89] The accuracy of results may also be affected by patient-specificfactors such as cardiac volume, patient size and perfusion defectsize. [10]…”
Section: Introductionmentioning
confidence: 99%
“…The effects of filtering have already been observed in many clinical studies. [20][21][22][23][24] However, no investigations of filtering effects on murine cardiac SPECT have yet been published.…”
mentioning