Facilitating high resolution mass spectrometry data processing for screening of environmental water samples: An evaluation of two deconvolution tools

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 39 publications
0
9
0
Order By: Relevance
“…HRMS instruments can screen for unknowns, due to exact mass measurements. This unique characteristic distinguishes it to other mass spectrometry instruments [203].…”
Section: High-resolution Mass Spectrometry (Hrms)mentioning
confidence: 96%
See 2 more Smart Citations
“…HRMS instruments can screen for unknowns, due to exact mass measurements. This unique characteristic distinguishes it to other mass spectrometry instruments [203].…”
Section: High-resolution Mass Spectrometry (Hrms)mentioning
confidence: 96%
“…Hybrid systems, such as HRMS hyphenated to a quadrupole, or linear ion trap (LTQ), such as the LTQ-Orbitrap, combine the tandem mass spectrometric capability that is associated with the LTQ with the high mass resolving power (up to 100,000 FWHM) and mass accuracy capability of the Orbitrap [202,203]. These hybrid configurations based on HRMS allow for the reliable interpretation of MS/MS spectra.…”
Section: High-resolution Mass Spectrometry (Hrms)mentioning
confidence: 99%
See 1 more Smart Citation
“…The environmental samples could contain thousands of peaks [16,17]. As a result, steps need to be taken to decrease the amount of peaks to a manageable number, calculate suitable molecular formulae, determine the isotopic patterns, and perform defect analysis of the mass defect and time prediction of the retention time [14,18,19].…”
Section: Introductionmentioning
confidence: 99%
“…In order to achieve this goal, removal of redundant ions is the first vital step. Now the conventionally used methods to remove interfering ions include sample analysis replicates, , solvent extraction blank, and control sample blank, ,, which can remove the unstable interfering ions, the noise ions from analytical process, and the useless ions in sample. Zeng et al developed an ion fusion strategy to subtract the isotopic ions, adduct ions and fragment ions coming from the same compound. , To further quickly determine risk compounds, on one hand, the in-house database usually was used. ,, However, the number of compounds in such in-house databases is limited.…”
mentioning