2019
DOI: 10.1007/s00216-019-02245-8
|View full text |Cite
|
Sign up to set email alerts
|

Facile fabrication of a novel disposable pencil graphite electrode for simultaneous determination of promising immunosuppressant drugs mycophenolate mofetil and tacrolimus in human biological fluids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(10 citation statements)
references
References 28 publications
0
7
0
Order By: Relevance
“…Upon increasing the potential scan rate, the anodic peak currents (Ipa) was increased with shift the oxidation potential to more positive values. The relationship between log Ipc (μA) and log ν (mV s − 1 ) can be expressed by the following equations: Ipa (μA) = 0.218 log ν (mVs − 1 ) + 87.47 (R 2 = 0.9951) and Ipa (μA) = 0.211 log ν (mVs − 1 ) + 80.07 (R 2 = 0.9959) for AZM and HCQ, respectively [49,50].…”
Section: Effect Of Potential Scan Ratementioning
confidence: 99%
“…Upon increasing the potential scan rate, the anodic peak currents (Ipa) was increased with shift the oxidation potential to more positive values. The relationship between log Ipc (μA) and log ν (mV s − 1 ) can be expressed by the following equations: Ipa (μA) = 0.218 log ν (mVs − 1 ) + 87.47 (R 2 = 0.9951) and Ipa (μA) = 0.211 log ν (mVs − 1 ) + 80.07 (R 2 = 0.9959) for AZM and HCQ, respectively [49,50].…”
Section: Effect Of Potential Scan Ratementioning
confidence: 99%
“…The formulas (3 × s/m) and (10 × s/m) were used to calculate the method's limit of detection (LOD) and limit of quantification (LOQ). 54 Where s denotes the measurement's standard deviation and m denotes the calibration curve's slope (or the sensitivity).…”
Section: Analytical Performance Parameters Of the Sensormentioning
confidence: 99%
“…Under the optimized conditions, the relation between the concentrations vs. anodic peak currents of three biomolecules was simultaneously investigated with the NiO/ MWCNT/NNaM/PGE electrochemical sensor using the sensitive DPV method in BR buffer solution (pH: 2.0) (Figure 3A). The linearity between anodic peak current vs. concentration for XT, TP, and TB are displayed in equations below; [21], respectively. Herein, s is the standard deviation of the sample and m is the slope of the calibration curve, or in other words, the sensitivity.…”
Section: The Simultaneous Detection Of Xt Tp and Tbmentioning
confidence: 99%
“…Glassy carbon [15] and carbon paste electrodes [16], boron-doped diamond electrodes [17], as well as screenprinted electrodes [18] have been widely using as electrochemical sensor platforms. Pencil graphite electrodes (PGEs) are unique electrochemical sensors due to their low cost, disposability, and commercial availability in stationeries [19][20][21]. PGEs enable to enhance the sensitivity towards the biomolecule sensing with a simple modification process involving immobilization of the modifiers to the electrode surface and transferring their physicochemical properties to this surface [13,22,23].…”
Section: Introductionmentioning
confidence: 99%