2009
DOI: 10.1080/00032710802677092
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a Praseodymium(III) PVC-Membrane Sensor Based on N′1,N′2-Bis(2-oxo-1,2-diphenylethylidene) ethanedihydrazide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 42 publications
(12 citation statements)
references
References 57 publications
0
12
0
Order By: Relevance
“…The solvent was then evaporated slowly, until an oily concentrated mixture was obtained. A Pyrex tube (3-5 mm in top) was dipped into the oily mixture for about 5 s, so that a transparent film of about 0.3 mm thickness was formed [33][34][35][36][37][38][39][40][41][42][43] . Afterwards, the tube was removed from the mixture, kept at the room temperature for about 12 h and filled with the internal filling solution (1.0×10 −3 M of HoCl 3 ).…”
Section: Preparation Of the Sensormentioning
confidence: 99%
“…The solvent was then evaporated slowly, until an oily concentrated mixture was obtained. A Pyrex tube (3-5 mm in top) was dipped into the oily mixture for about 5 s, so that a transparent film of about 0.3 mm thickness was formed [33][34][35][36][37][38][39][40][41][42][43] . Afterwards, the tube was removed from the mixture, kept at the room temperature for about 12 h and filled with the internal filling solution (1.0×10 −3 M of HoCl 3 ).…”
Section: Preparation Of the Sensormentioning
confidence: 99%
“…In comparison, potentiometric ion selective sensors offer advantages of low cost, portability, selectivity, and simple operatory. They also provide an analysis method without destruction of sample [8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…Many techniques have been used for determination of Gd which most of them have been spectroscopic methods such as inductively coupled Plasma-mass spectrometry (ICP-MS), atomic emission spectroscopy, electron spin resonance, laser-based multi step resonance ionization, phosphorescence opto-sensing, high-resolutionˆI3-spectroscopy, timeresolved fluorimetry, spectrophotofluorimetric determination, quenching of gadolinium fluorescence and some nucleic methods. Recently, several greatly selective and sensitive PVC-membrane ion-selective electrodes for various metal ions have been reported [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] . This research focuses on the introduction of a highly Gd(IIII)-selective sensor based on 3-methyl-1H-1,2,4-triazole-5-thiol (MTH) (Figure 1), as an ionophore for determination of Gd(III) ion concentration.…”
Section: Introductionmentioning
confidence: 99%