Fabrication of a novel holmium(III) PVC membrane sensor based on 4-chloro-1,2-bis(2-pyridinecarboxamido)benzene as a neutral ionophore

Abstract: This paper introduces the development of an original PVC membrane electrode, based on 4-chloro-1,2-bis(2-pyridinecarboxamido)benzene (CBPB) as a suitable carrier for the Ho 3+ ion. The electrode presents a Nernstian slope of 19.7 ± 0.3 mV per decade for the Ho 3+ ions across a broad working concentration range from 1.0 · 10 -6 to 1.0 · 10 -2 M. The lower detection limit was 8.5 · 10 -7 M in the pH range 2.7-9.8, while the response time was rapid (<15 s). Therefore, this potentiometric sensor displayed good sel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2008
2008
2013
2013

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 81 publications
(13 citation statements)
references
References 29 publications
0
13
0
Order By: Relevance
“…Thus, a quick, convenient, fast method is required to monitor neodymium in large number of environmental samples. Recently many papers for lanthanide ions have been reported La [12][13][14], Ce [15][16][17][18][19][20][21], Pr [22], Sm [23], Tb [24], Ho [25] and Yb [26] ions.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, a quick, convenient, fast method is required to monitor neodymium in large number of environmental samples. Recently many papers for lanthanide ions have been reported La [12][13][14], Ce [15][16][17][18][19][20][21], Pr [22], Sm [23], Tb [24], Ho [25] and Yb [26] ions.…”
Section: Introductionmentioning
confidence: 99%
“…was dipped into the mixture for about 5 s, so that a transparent membrane of about 0.3 mm thickness was formed. [40][41][42][43][44][45][46][47][48][49][50] The tube was then pulled out from the mixture and kept at the room temperature for about 24 h. The tube was then filled with internal filling solution (1.0 × 10 -3 M of AgNO 3 ). The electrode was finally conditioned by soaking in a 1.0 × 10 -3 M AgNO 3 solution for 24 h. A silver/silver chloride wire was used as an internal reference electrode.…”
Section: Electrode Preparationmentioning
confidence: 99%
“…Recently, several studies concerning the selective and sensitive PVCmembrane ion-selective electrodes have been reported for some ions (Zamani, Abedini-Torghabeh, and Ganjali 2006a;Zamani, Rajabzadeh, Ganjali, and Nourozi 2007;Liu et al 2006;Zamani, Rajabzadeh, and Ganjali 2006a, 2007c, 2007dLuo, Chai, and Yuan 2007;Zamani, Ganjali, Norouzi, Adib, and Aceedy 2006;Zhang et al 2007;Zamani, 556 H. A. Zamani et al Ganjali, andAdib 2007a, 2007b;Zamani, Ganjali, Nourozi, and Meghdadi 2007;Behmadi et al 2007;Zamani, Ganjali, and Seifi 2007;Pooyamanesh et al 2007). The aim of this work is fabrication of a highly selective and sensitive praseodymium(III) PVC membrane electrode based on N 01 ,N 02 -bis(2-oxo-1,2-diphenylethylidene)ethanedihydrazide (BEH) as an excellent ionophore for the selective and sensitive potentiometric determination of Pr(III) ion over a wide concentration range (Fig.…”
Section: Introductionmentioning
confidence: 99%